ABC cable 4x50mm 4x70mm 4x70mm2 PVC/XLPE Insulation cable Overhead Insulated Cable
Negotiable
Min.Order:1
Henan Kingyear Aluminum Industrial Co., Ltd.
PVC/XLPE/HDPE abc cable for sale south africa south america market
3 core aluminum conductor ABC 185mm2 33kV ABC aerial bundle cable ABC cable Price
0.6/1KV Overhead Aluminum AAAC Conductor XLPE Insulated ABC/CAAI Cable 35mm ABC Cable
Abc Cable Wire 3 Core Aluminum 3*120mm Xlpe Insulated Aerial Bundle With High Quality
0.6/1kv 3 Core 185mm 240mm Aluminum Abc Cable Xlpe Insulated Aerial Bundle Conductors
Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | ||||||||||||||
Size & No.of wires | Insulation Thick (mm) | Nominal Dia.(mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Aluminum | ( A ) | |||||||||||
Bare | OD | |||||||||||||||||
AAC | ||||||||||||||||||
Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 | |||||||||
Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 | |||||||||
Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 | |||||||||
Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 | |||||||||
Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 | |||||||||
Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 | |||||||||
Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 | |||||||||
Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | - | 56.5 | 233.6 | 158 | |||||||||
Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
AAAC | ||||||||||||||||||
Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 | |||||||||
VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 | |||||||||
Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 | |||||||||
Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 | |||||||||
Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 | |||||||||
Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
ACSR | ||||||||||||||||||
Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 | |||||||||
Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 | |||||||||
Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 | |||||||||
Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 | |||||||||
Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 | |||||||||
Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 | |||||||||
Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 | |||||||||
Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 | |||||||||
Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Duplex Service Drop Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting.For service at 600 volts or lower at a conductor temperature of 75°C maximum. | ||||||||||||||||||
Triplex Service Drop Application: To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation. | ||||||||||||||||||
Quadruplex Service Drop. Applications:Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors. |