ASTM B399 Greely 927.2MCM 26/7 Standard AAC AAAC ACSR Aluminum Alloy Compact Compressed Conductor
Negotiable
Min.Order:1
Henan Kingyear Aluminum Industrial Co., Ltd.
Wholesale Price AAAC/AAC/ACSR Aluminum Line Wire AAAC Conductor For Overhead Application
NFC 34-125 Bare Aaac Conductor 2/0awg Overhead Aluminum Conductor Aaac Cable Power Cable
240mm ACSR/AAC/AAAC Bare Aluminum Cable Conductor With Best Price
150 mm2 1000mm2 Kabel 240mm2 Oiled Aaac Conductor Overhead Stranded Aluminum Alloy Cable
50mm2 AAC/AAAC/ACSR Aluminum Bare Conductor Bare Cable Factory Wholesale Price
7/2.5mm Bare Conductor Factory Price AAAC All Aluminium Conductor IEC 61089
Duplex service drop | ||||||||||||||||||
Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | ||||||||||||||
Size & No.of wires | Insulation Thick(mm) | Nominal Diameter (mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Aluminum | ( A ) | |||||||||||
Bare | OD | |||||||||||||||||
AAC | ||||||||||||||||||
Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 | |||||||||
Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 | |||||||||
Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 | |||||||||
Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 | |||||||||
Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 | |||||||||
Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 | |||||||||
Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 | |||||||||
Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | - | 56.5 | 233.6 | 158 | |||||||||
Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
AAAC | ||||||||||||||||||
Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 | |||||||||
VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 | |||||||||
Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 | |||||||||
Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 | |||||||||
Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 | |||||||||
Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
ACSR | ||||||||||||||||||
Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 | |||||||||
Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 | |||||||||
Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 | |||||||||
Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 | |||||||||
Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 | |||||||||
Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 | |||||||||
Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 | |||||||||
Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 | |||||||||
Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Applications of Duplex ABC cable | To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum. | |||||||||||||||||
Applications of Triplex ABC cable | To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation. | |||||||||||||||||
Applications of Quadruplex ABC cable | Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors |