Aac/aaac/acsr All Aluminum Alloy Conductor Bare Cable Price List
Negotiable
Min.Order:1
Henan Kingyear Aluminum Industrial Co., Ltd.
Duplex service drop | ||||||||||||||||||
Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | ||||||||||||||
Size & No.of wires | Insulation Thick(mm) | Nominal Diameter (mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Aluminum | ( A ) | |||||||||||
Bare | OD | |||||||||||||||||
AAC | ||||||||||||||||||
Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 | |||||||||
Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 | |||||||||
Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 | |||||||||
Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 | |||||||||
Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 | |||||||||
Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 | |||||||||
Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 | |||||||||
Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | - | 56.5 | 233.6 | 158 | |||||||||
Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
AAAC | ||||||||||||||||||
Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 | |||||||||
VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 | |||||||||
Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 | |||||||||
Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 | |||||||||
Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 | |||||||||
Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
ACSR | ||||||||||||||||||
Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 | |||||||||
Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 | |||||||||
Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 | |||||||||
Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 | |||||||||
Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 | |||||||||
Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 | |||||||||
Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 | |||||||||
Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 | |||||||||
Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Applications of Duplex ABC cable | To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum. | |||||||||||||||||
Applications of Triplex ABC cable | To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation. | |||||||||||||||||
Applications of Quadruplex ABC cable | Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors |
IEC 61089 | ||||||||||||
Code Name | Nominal | No./Nominal diameter of wires | Approximate Overall Diameter | Approximate Weight | Nominal Breaking Load | Nominal DC Resistance at 20°C | ||||||
mm2 | No./mm | mm | kg/km | KN | ohm/km | |||||||
10 | 10 | 7/1.35 | 4.05 | 27.4 | 2 | 2.8633 | ||||||
16 | 16 | 7/1.71 | 5.13 | 43.8 | 3 | 1.7896 | ||||||
25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 | ||||||
40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 | ||||||
63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.4 | 0.4545 | ||||||
100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 | ||||||
125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.3 | 0.2302 | ||||||
160 | 160 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 | ||||||
200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 | ||||||
250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 | ||||||
315 | 315 | 37/3.29 | 23.03 | 867.9 | 52 | 0.0916 | ||||||
400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 | ||||||
450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 | ||||||
500 | 500 | 37/4.15 | 29.05 | 1377.6 | 80 | 0.0577 | ||||||
560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 | ||||||
630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 | ||||||
710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 | ||||||
800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 | ||||||
900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 | ||||||
1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 | ||||||
1120 | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 | ||||||
1250 | 1250 | 91/4.18 | 45.98 | 3452.6 | 200 | 0.0231 | ||||||
1400 | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 | ||||||
1500 | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 |
ASTM B 399/B 399M | ||||||||||||||||
Code Name | Total Area | 1350 Grade Equivalent | No./Dia. of Wire | Approx. Overall Diameter | Approx. Weight | Calculated Breaking Load | Max.DC Resista-nce at 20° C | |||||||||
AWG or MCM | mm2 | (Approx.) AWG or MCM | No. / mm | mm | kg/km | kN | Ohm/km | |||||||||
Akron | 30.6 | 15.5 | 6 | 7/1.68 | 5.04 | 43 | 4.9 | 2.1588 | ||||||||
Alton | 48.7 | 24.7 | 4 | 7/2.12 | 6.36 | 68 | 7.8 | 1.3557 | ||||||||
Ames | 77.5 | 39.2 | 2 | 7/2.67 | 8.01 | 108 | 12.4 | 0.8547 | ||||||||
Azusa | 123.3 | 62.4 | 1 | 7/3.37 | 10.11 | 171 | 18.9 | 0.5365 | ||||||||
Anaheim | 155.4 | 78.6 | 2/0 | 7/3.78 | 11.34 | 216 | 23.8 | 0.4264 | ||||||||
Amherst | 195.7 | 99.3 | 3/0 | 7/4.25 | 12.75 | 272 | 30 | 0.3373 | ||||||||
Alliance | 246.9 | 125.1 | 4/0 | 7/4.77 | 14.31 | 343 | 37.8 | 0.2678 | ||||||||
Butte | 312.8 | 158.6 | 266.8 | 19/3.26 | 16.3 | 435 | 46.5 | 0.2112 | ||||||||
Canton | 394.5 | 199.9 | 336.4 | 19/3.66 | 18.3 | 548 | 58.6 | 0.1676 | ||||||||
Cairo | 465.4 | 236.4 | 397.5 | 19/3.98 | 19.9 | 649 | 69.3 | 0.1417 | ||||||||
Darien | 559.5 | 283.6 | 477 | 19/4.36 | 21.8 | 778 | 83.1 | 0.1181 | ||||||||
Elgin | 652.6 | 331 | 556.5 | 19/4.71 | 23.55 | 908 | 97 | 0.1012 | ||||||||
Flint | 740.8 | 374.5 | 636 | 19/3.59 | 25.13 | 1028 | 107.4 | 0.0894 | ||||||||
Greeley | 927.2 | 469.6 | 795 | 19/4.02 | 28.14 | 1289 | 134.6 | 0.0713 |
AAAC conductor-ASTM B 399B 399M | ||||||||||||||
Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* | ||||||||
AWG&MCM | mm^2 | No./mm | mm | kg/km | KN | Ω/Km | A | |||||||
6 | 13.2 | 7/1.55 | 4.65 | 36.2 | 4.18 | 2.5361 | 69 | |||||||
4 | 21.1 | 7/1.96 | 5.88 | 57.9 | 6.69 | 1.586 | 93 | |||||||
2 | 33.5 | 7/2.47 | 7.41 | 92 | 10.6 | 0.9987 | 123 | |||||||
0 | 53.5 | 7/3.12 | 9.36 | 146.8 | 17 | 0.62592 | 165 | |||||||
2/0 | 67.3 | 7/3.50 | 10.5 | 184.8 | 20.4 | 0.49738 | 190 | |||||||
3/0 | 84.9 | 7/3.93 | 11.79 | 233 | 25.7 | 0.3945 | 219 | |||||||
4/0 | 107 | 7/4.42 | 13.26 | 294.7 | 32.5 | 0.31188 | 253 | |||||||
250 | 126 | 19/2.91 | 14.55 | 346.7 | 38.8 | 0.26509 | 280 | |||||||
300 | 152 | 19/3.19 | 15.95 | 416.7 | 46.6 | 0.22059 | 313 | |||||||
350 | 178 | 19/3.45 | 17.25 | 487.3 | 52 | 0.1886 | 345 | |||||||
400 | 203 | 19/3.69 | 18.45 | 557.5 | 59.5 | 0.16486 | 375 | |||||||
450 | 228 | 19/3.91 | 19.55 | 626 | 66.8 | 0.14683 | 402 | |||||||
500 | 253 | 19/4.12 | 20.6 | 695 | 74.2 | 0.13224 | 429 | |||||||
550 | 279 | 37/3.10 | 21.7 | 766.2 | 83.9 | 0.11995 | 455 | |||||||
600 | 303 | 37/3.23 | 22.61 | 831.9 | 91 | 0.11049 | 478 | |||||||
650 | 330 | 37/3.37 | 23.59 | 905.5 | 94.9 | 0.1015 | 504 | |||||||
700 | 354 | 37/3.49 | 24.43 | 971.2 | 101 | 0.09464 | 525 | |||||||
750 | 381 | 37/3.62 | 25.34 | 1045 | 109 | 0.08796 | 549 | |||||||
800 | 404 | 37/3.73 | 26.11 | 1109 | 116 | 0.08285 | 569 | |||||||
900 | 456 | 37/3.96 | 27.72 | 1250 | 131 | 0.07351 | 612 | |||||||
1000 | 508 | 37/4.18 | 29.26 | 1393 | 146 | 0.06597 | 653 | |||||||
1250 | 631 | 61/3.63 | 32.67 | 1732 | 179 | 0.05306 | 743 | |||||||
1500 | 759 | 61/3.98 | 35.82 | 2082 | 215 | 0.04414 | 827 | |||||||
1750 | 886 | 61/4.30 | 38.7 | 2431 | 251 | 0.03781 | 904 |