0.6/1KV Low Voltage 1 2 3 4 5 Core Copper Conductor XLPE PVC Insulated Underground Armoured Power Cable
Negotiable
Min.Order:1
Rubber Cable Xlpe pvc Rubber Insulation Power Cable Heat Resistant welding Power Cable
Rubber power Cable price copper conductor EPR insulation Rubber sheath cable Coal Mining cable
8.7/15KV Rubber Flexible UGEFP Cables CPE Jacket EPR Insulated Copper Trailing Mining Cable
UGEFP Tunnel Boring Machine Cable Shield Machine High Voltage Rubber Cable
Model: | Insulated copper/aluminum core power cable | ||||
Conductor | Aluminum or Copper | ||||
Armoured | SWA(Steel Wire Armoured) / STA(Steel Tape Armoured) or Non-Armoured | ||||
Insulation | PVC/LSF/Fire Resistant | ||||
Cores | 1, 2, 3, 4, 5, 3+1, 4+1, 3+2, Customized | ||||
Section Area | 1.5mm2-300mm2 | ||||
Standard | IEC 60502, BS 7870, GB/T12706 or other. | ||||
Packaging | Iron Or Wooden Drum | ||||
Application | Building, Engineered, Railway, Plant construction, Shool, Hospital, Underground and so on. | ||||
Market | South&north America/Europe/ Asia/ Australia/Africa and etc. | ||||
Trade Term: | FOB/CIF/CFR/CNF/EXW/DDU/DDP | ||||
Our advantage | One-stop shopping; High quality; Competitive price; Timely delivery; Technical support; | ||||
Customized | OEM/ ODM |
Type | Name | Application | ||
Cu Conductor | Al Conductor | |||
YJV | YJLV | XLPE Insulated,PVC or PE S heathed Power Cable | For laying in door,tunnel,channel and underground.Unable to bear external mechanical force,but bear the traction force during laid. | |
YJV22 | YJLV22 | XLPE Insulated,Steel Tape Armoured,PVC or PE Sheathed Power Cable | For laying in tunels in door,tunnel,channel and underground.Able to bear external mechanical force,but unable to bear large pulling force. | |
YJV32 | YJLV32 | XLPE Insulated,Fine Steel Wire Armoured,PVC or PE Sheathed Power Cable | For laying in shaft with large difference of level.Able to bear external mechanical force,and moderable pulling force. | |
YJV42 | YJLV42 | XLPE Insulate,Thick Steel Wire Armoured,PVC or PE Sheathed Power Cable | Able to bear positive pressure and pulling force. |
Sectional area | Outer diameter of Low voltage YJV/YJLV unarmoured cable (mm) | ||||||||||||||
1 | 2 | 3 | 4 | 3+1 | 5 | 3+2 | 4+1 | ||||||||
1.5 | 6.1 | 9.5 | 10.2 | 11 | 10.8 | 11.8 | 11.2 | 11.5 | |||||||
2.5 | 6.7 | 10.3 | 11.2 | 12.2 | 11.8 | 13.2 | 12.5 | 12.8 | |||||||
4 | 7.2 | 12.7 | 12.8 | 14.5 | 13.8 | 16.2 | 14.3 | 15 | |||||||
6 | 7.5 | 13.7 | 14.5 | 15.8 | 14.9 | 17.1 | 15.6 | 16 | |||||||
10 | 8.5 | 15.6 | 15.8 | 18 | 17.5 | 20 | 18.3 | 19.2 | |||||||
16 | 9.5 | 18 | 18 | 21 | 20.1 | 24 | 21.3 | 22.5 | |||||||
25 | 11.2 | 20.5 | 21.5 | 25 | 23.1 | 28.5 | 24.5 | 26.5 | |||||||
35 | 12 | 22.5 | 24 | 28 | 25.3 | 32 | 26.4 | 28.2 | |||||||
50 | 14 | 25.5 | 27 | 30 | 28 | 33 | 30.6 | 31.8 | |||||||
70 | 15.5 | 29.5 | 31 | 34 | 32.5 | 37 | 34.2 | 35 | |||||||
95 | 17.2 | 32.7 | 35 | 39 | 36 | 43 | 38.6 | 40 | |||||||
120 | 19 | 36.5 | 39 | 43 | 41 | 48 | 42.8 | 44 | |||||||
150 | 21.8 | 41.5 | 43.5 | 48 | 47 | 52 | 48.2 | 49 | |||||||
185 | 23.5 | 45.5 | 48.5 | 54 | 50.5 | 59.5 | 53.7 | 55 |
Sectional area | Outer diameter of Low voltage YJV/YJLV armoured cable (mm) | ||||||||||||||
1 | 2 | 3 | 4 | 3+1 | 5 | 3+2 | 4+1 | ||||||||
1.5 | / | / | / | / | / | / | / | / | |||||||
2.5 | / | / | / | / | / | / | / | / | |||||||
4 | / | 16 | 16.9 | 17.6 | 17.3 | 18.3 | 17.9 | 18.1 | |||||||
6 | / | 17 | 17.8 | 19 | 18.5 | 20.2 | 19.2 | 19.7 | |||||||
10 | / | 18.5 | 19.4 | 21.2 | 21.1 | 22.5 | 21.9 | 22.2 | |||||||
16 | / | 20.5 | 22.6 | 23 | 23.7 | 24.9 | 24.9 | 24.9 | |||||||
25 | / | 23 | 25.5 | 27 | 26.7 | 28.5 | 28.1 | 28.3 | |||||||
35 | / | 25 | 28 | 32 | 28.9 | 35 | 30.2 | 32.2 | |||||||
50 | / | 27.5 | 31 | 33.5 | 32 | 36 | 35.2 | 35.8 | |||||||
70 | / | 32.5 | 36 | 38 | 36 | 40 | 38.8 | 39 | |||||||
95 | / | 36 | 39.9 | 45 | 40.5 | 49.5 | 43.2 | 44 | |||||||
120 | / | 39.5 | 43 | 46.5 | 44.7 | 51.6 | 47.6 | 49 | |||||||
150 | / | 44 | 48 | 51.5 | 48 | 55 | 52.8 | 54 | |||||||
185 | / | 48.5 | 52 | 58 | 53 | 65 | 58.3 | 59 |
Sectional area | Outer diameter of Low voltage VV/VLV unarmoured cable (mm) | ||||||||||||||
1 | 2 | 3 | 4 | 3+1 | 5 | 3+2 | 4+1 | ||||||||
1.5 | 6.6 | 10.6 | 11 | / | / | / | / | 16 | |||||||
2.5 | 7 | 11.5 | 11.9 | / | / | / | / | 17 | |||||||
4 | 7.9 | 13.6 | 13.8 | 14.8 | 14.6 | 16 | 15.5 | 19 | |||||||
6 | 8.5 | 14.5 | 14.9 | 16 | 16 | 17 | 17.5 | 23.5 | |||||||
10 | 9.7 | 16.9 | 17.8 | 19.3 | 18.9 | 19 | 19 | 28 | |||||||
16 | 10.7 | 18.9 | 19.9 | 21.8 | 21.5 | 24 | 23 | 31 | |||||||
25 | 12.4 | 22.8 | 24.6 | 26.5 | 25.6 | 29 | 27 | 32.5 | |||||||
35 | 13.6 | 25.1 | 25.4 | 29.2 | 27.9 | 32 | 28 | 36 | |||||||
50 | 15.8 | 25.2 | 26.8 | 33.7 | 28.7 | 33 | 32.5 | 41.5 | |||||||
70 | 17.6 | 27 | 27.7 | 34.8 | 32.5 | 36 | 36 | 45 | |||||||
95 | 20.7 | 28.8 | 32.1 | 39.6 | 37.3 | 42 | 41 | 49 | |||||||
120 | 22 | 31.2 | 35.1 | 42.9 | 39.9 | 45 | 45 | 54 | |||||||
150 | 24 | 34.7 | 38.9 | 47.8 | 44.6 | 50 | 48 | 61 | |||||||
185 | 26.5 | 37.5 | 42.9 | 53 | 50.3 | 55 | 53 | 67 |
Sectional area | Outer diameter of Low voltage VV/VLV armoured cable (mm) | ||||||||||||||
1 | 2 | 3 | 4 | 3+1 | 5 | 3+2 | 4+1 | ||||||||
1.5 | / | / | / | / | / | / | / | 19 | |||||||
2.5 | / | / | / | / | / | / | / | 20 | |||||||
4 | / | 16.7 | 17.5 | 18.6 | 18.2 | 19 | 18.5 | 22.5 | |||||||
6 | / | 17.7 | 18.5 | 19.9 | 19.5 | 20.5 | 20 | 26.5 | |||||||
10 | 13.9 | 20.3 | 21.5 | 23 | 22.5 | 23 | 22 | 32 | |||||||
16 | 14.9 | 22.9 | 23.8 | 25.5 | 24.9 | 27 | 26 | 35 | |||||||
25 | 16.7 | 25.3 | 27.6 | 28.5 | 28.4 | 34 | 30 | 36 | |||||||
35 | 17.8 | 27.6 | 29 | 32.5 | 30.9 | 36 | 32 | 40 | |||||||
50 | 20 | 25.5 | 29.8 | 37.1 | 34.7 | 37 | 37 | 46 | |||||||