Flexible Mining Wire MYQ MY MYP 6/10KV Rubber Cable copper conductor EPDM Insulated Sheath Cable Mining Cable
Negotiable
Min.Order:1
8.7/15KV Rubber Flexible UGEFP Cables CPE Jacket EPR Insulated Copper Trailing Mining Cable
UGEFP Tunnel Boring Machine Cable Shield Machine High Voltage Rubber Cable
UGEFP Coal Mine Strong Electric Cables Energy Transmission Mining Cable High Voltage Rubber Cable
KVV KVVP 0.45/0.75KV 0.6/1kV Multicore Flexible Control Cable copper Conductor electric wires
Colored PVC Coated Electrical Cable Wire House Wiring Electrical Cable Application BV BVV BVR
Construction Material Steel Grouting Sleeves Grout Filled Rebar Coupler
Model: | Insulated copper core Mining rubber cable | ||||
Conductor | Copper | ||||
Voltage | 300/500V, 0.38/0.66KV, 0.66/1.14 kV, 1.9/3.3 kV, 3.6/6 kV, 6/10 kV, 8.7/10 kV | ||||
Insulation | PVC/LSF/Fire Resistant/PER/CPE | ||||
Cores | 2, 3+1, Customized | ||||
Section Area | 1.5mm2---400mm2 | ||||
Max Operating Temperature | 90 ℃ | ||||
Standard | IEC 60502, BS 7870, GB/T12706 or other. | ||||
Packaging | Iron Or Wooden Drum | ||||
Application | At high mechanical stresses for the connection of heavy-duty underground mining, industrial and construction equipment, in dry and damp areas, and outdoors. The cable is largely flame-resistant and oil-proof. | ||||
Market | South&north America/Europe/ Asia/ Australia/Africa and etc. | ||||
Trade Term: | FOB/CIF/CFR/CNF/EXW/DDU/DDP | ||||
Our advantage | One-stop shopping; High quality; Competitive price; Timely delivery; Technical support; | ||||
Customized | OEM/ ODM |
Type | Number of cores | Nominal Section (mm) | Nominal section of power core(mm2) | Nominal section of ground core(mm2) | ||||||||
Number | Insulation thickness | Jacket thickness | ||||||||||
MYQ— 0.3/0.5 KV | 2 3+1 | 1.0-6 1.5-6 | 1/1.5/2.5/4/6 1.5/2.5/4/6 | 0.6—1 | / 1/1.5/2.5/4 | 1.5—2.5 | ||||||
MY—0.38/0.66 KV | 3+1 | 4-185 | 4/6/10/16/25/50/70/95/120/150/185 | 1.4—2.4 | 4/6/10/16/25/35/50 | 3.5—6 | ||||||
MYP—0.38/0.66 KV | 3+1 | 4-185 | ||||||||||
MYP—0.66/1.14 KV | 3+1 | 10-185 | 10/16/25/50/70/95/120/150/185 | 1.8—2.6 | 10/16/25/35/50 | 4.5—6.5 | ||||||
MYP—1.9/3.3 KV | 3+1 | 16-185 | 16/25/50/70/95/120/150/185 | 2.6—3.4 | 16/25/35/50 | 4.5—6 | ||||||
MYP— 3.6/6 KV | 3+1 | 16-185 | 16/25/50/70/95/120/150/185 | 1.6—4.5 | 16/25/35/50 | 4—6.5 | ||||||
MYP— 6/10 KV | 3+1 | 16-185 | 16/25/50/70/95/120/150/185 | 4.5—5 | 16/25/35/50 | 5.5—7 | ||||||
MYP— 8.7/10 KV | 3+1 | 16-185 | 16/25/50/70/95/120/150/185 | 6.5 | 16/25/35/50 | 6—7 | ||||||
Notice: 1. Cable conductor long-term allowed working temperature is 90 ℃ 2. Max operating temperature of conductor when short-circuit (5s maximum duration ) is no more than 160-250℃ 3. The ambient temperature of cable installation≥0℃ |