Shearer Flexible Cables Type MC & MCP, 0.38/0.66kV, 0.66/1.14kV,1.9/3.3kV
Negotiable /Piece
Min.Order:1000 Pieces
Jiangsu Shangshang Cable Group Co., Ltd
Shearer Flexible Cables With Metallic Screen Type MCPT & MCPTJ, 0.66/1.14kV,1.9/3.3kV
Movable Flexible Cables Type MY & MYP, 0.38/0.66kV, 0.66/1.14kV
Rubber Sheathed Flexible VFD Cable Type MVFP, 0.38/0.66kV, 0.66/1.14kV, 1.9/3.3kV
Shuttle Car Cable, Type MSCPTJB 0.38/0.66kV, 0.66/1.14kV, 1.9/3.3kV
Reinforced Shearer Flexible Cable, Type MCPB 0.66/1.14kV,1.9/3.3kV
MC-0.38/0.66kV:
Conductor:flexible tinned copper conductor (class 5)
Insulation: ethylene-propylene rubber (EPR)
Core arrangement: three power cores plus one earth core, or three power cores plus one earth core and multi-control cores
Outer sheath: Chlorinated Polyethylene(CPE)
MCP-0.38/0.66kV and MCP-0.66/1.14kV:
Conductor: flexible tinned copper conductor (class 5)
Insulation: ethylene-propylene rubber (EPR)
Insulation screen: semi-conducting tape screen over power core insulation
Core arrangement: three power cores plus one earth core, or three power cores plus one earth core and multi-control cores
Outer sheath: Chlorinated Polyethylene(CPE)
MCP-1.9/3.3kV:
Conductor: flexible tinned copper conductor (class 5)
Insulation: ethylene-propylene rubber (EPR)
Insulation screen: extruded semi-conducting screen over power core insulation
Core arrangement: three power cores plus one earth core, or three power cores plus one earth core and multi-control cores
Outer sheath: Chlorinated Polyethylene(CPE)
Type of core | Number of cores | Conductor CSA (mm2) |
Power core | 3 | 10 ∽ 185 |
Earth core | 1 | 4, 6, 10, 16, 25,35 |
Control cores (optional) | 3, 4, 7,10 | 2.5, 4, 6, 10 |
Three power cores: red, white, blue
Earth core: black
Control cores: white color with printed black numbers
USAGE CHARACTERISTICS:
Rated voltage: 0.38/0.66kV, 0.66/1.14kV, 1.9/3.3kV
Maximum continuous conductor operating temperature: 90℃
Maximum conductor short circuit temperature: 250℃ (maximum duration 5Sec.)
Minimum installation ambient temperature: 0℃
Minimum bending radius for installation: 6xO.D.
CERTIFICATION:
MA certification