As a motor protection component, the motor protector effectively guarantees the safe operation of the motor, replaces the thermal relay, and realizes the motor control automation by using advanced communication technology.
FEATURES AT A GLANCE
Feature
Protection functions: overload protection, blocking protection, blocking protection, external fault protection, current imbalance protection, starting overtime protection, grounding protection, phase failure protection, contactor breaking protection, underloadprotection;
Start mode: protection mode, direct start mode, bidirectional reversible start, star / delta start, autotransformer start;
Monitoring functions: 3 phase current, A phase voltage, active power, reactive power, power factor, frequency, active energy, work energy, grounding current, leakage current, 4 ~ 20mA analog input, heat capacity;
Optional protection: leakage protection, TE protection, temperature protection, analog input protection, overvoltage protection,undervoltage protection, under power protection, undervoltage restart;
Special features: analog input, digital input, relay output
Display: large-screen LCD display, high quality, wide viewing angle, high visibility;
Communication: RS485 communication, Modbus-RTU;
Applicable motor: Motor rated voltage: 380V ~ 660V, rated power 0.25 ~ 250kW
Start mode: protection mode, direct start mode, bidirectional reversible start, star / delta start, autotransformer start;
Monitoring functions: 3 phase current, A phase voltage, active power, reactive power, power factor, frequency, active energy, work energy, grounding current, leakage current, 4 ~ 20mA analog input, heat capacity;
Optional protection: leakage protection, TE protection, temperature protection, analog input protection, overvoltage protection,undervoltage protection, under power protection, undervoltage restart;
Special features: analog input, digital input, relay output
Display: large-screen LCD display, high quality, wide viewing angle, high visibility;
Communication: RS485 communication, Modbus-RTU;
Applicable motor: Motor rated voltage: 380V ~ 660V, rated power 0.25 ~ 250kW
Details Images
Product Paramenters
KPM60 - KPM60 Low-voltage motor protection controller-Technical parameters | ||||||||
Working power source | Operating Voltage | AC85~265VDC80~300V | ||||||
Rated power | <5VA | |||||||
Input voltage | Rated voltage | 380V-660V | ||||||
Frequency range | 45~65Hz | |||||||
Input current | Rated current | 5A,32A, 100A, 250A, 500A | ||||||
Frequency range | 45~65Hz | |||||||
InputOutput | Switch value input | 8-way passive main line contact DI input, internal supply DC24V power source | ||||||
Relay output | 4-way DO output,Contact capacity 250VAC5A,30VDC5A | |||||||
Analog output | Output range 4~20mA,Programmable | |||||||
Temperature input | Measure range 0℃~100℃ | |||||||
Measurement accuracy | Current | ±1.0%(10%Ie~120%Ie) | ||||||
Leakage current | ±1.0%(5%Ise~100%Ise) | |||||||
Voltage | ±0.5%(20%Ue~150%Ue) | |||||||
Frequency | ±0.02Hz(45Hz~65Hz) | |||||||
Power factor | ±1.0%(-1~1) | |||||||
Energy | ±2.0% | |||||||
Power | ±2.0% | |||||||
Communication | Communication interface | RS485,Photoelectric isolation interface | ||||||
Communication protocol | Modbus-RTU,1200~38400bps Profibus-DP,9600~12Mbps | |||||||
Electrical insulation | Power frequency withstand voltage | AC2kVmin~1mA Input-output-power source | ||||||
Insulation resistance | >50MΩ | |||||||
Impact voltage | 5kV(Peak),1.250us | |||||||
Working environment | Operating temperature | -25℃ ~ +70℃ | ||||||
Relative humidity | 5%~95% No condensation | |||||||
Storage temperature | -30℃ ~ +75℃ |
1. Overload protection
2. Stall protection
3. Current imbalance protection
4. Start overtime protection
5. Ground protection
6. Phase failure protection
7. Contactor sectional current protection
8. Underload protection
9. Blocking protection
10. Leakage Protection
11.TE time protection
12.Overvoltage protection
13.Undervoltage protection
14.Under-power protection
15.Power factor protection
16.Undervoltage restart
17.Phase sequence protection
18.Temperature protection
19.External fault protection
2. Stall protection
3. Current imbalance protection
4. Start overtime protection
5. Ground protection
6. Phase failure protection
7. Contactor sectional current protection
8. Underload protection
9. Blocking protection
10. Leakage Protection
11.TE time protection
12.Overvoltage protection
13.Undervoltage protection
14.Under-power protection
15.Power factor protection
16.Undervoltage restart
17.Phase sequence protection
18.Temperature protection
19.External fault protection