2021 HOT SALES Low voltage intelligent digital programmable motor protection relay controller multifunction energy meter

Product Features

Product Overview


As a motor protection component, the motor protector effectively guarantees the safe operation of the motor, replaces the thermal relay, and realizes the motor control automation by using advanced communication technology.
FEATURES AT A GLANCE
Feature
Protection functions: overload protection, blocking protection, blocking protection, external fault protection, current imbalance protection, starting overtime protection, grounding protection, phase failure protection, contactor breaking protection, underloadprotection;
Start mode: protection mode, direct start mode, bidirectional reversible start, star / delta start, autotransformer start;
Monitoring functions: 3 phase current, A phase voltage, active power, reactive power, power factor, frequency, active energy, work energy, grounding current, leakage current, 4 ~ 20mA analog input, heat capacity;
Optional protection: leakage protection, TE protection, temperature protection, analog input protection, overvoltage protection,undervoltage protection, under power protection, undervoltage restart;
Special features: analog input, digital input, relay output
Display: large-screen LCD display, high quality, wide viewing angle, high visibility;
Communication: RS485 communication, Modbus-RTU;
Applicable motor: Motor rated voltage: 380V ~ 660V, rated power 0.25 ~ 250kW
Details Images
Product Paramenters
KPM60 - KPM60 Low-voltage motor protection controller-Technical parameters
Working power source
Operating Voltage
AC85~265VDC80~300V
Rated power
<5VA
Input voltage
Rated voltage
380V-660V
Frequency range
45~65Hz
Input current
Rated current
5A,32A, 100A, 250A, 500A
Frequency range
45~65Hz
InputOutput
Switch value input
8-way passive main line contact DI input, internal supply DC24V power source
Relay output
4-way DO output,Contact capacity 250VAC5A,30VDC5A
Analog output
Output range 4~20mA,Programmable
Temperature input
Measure range 0℃~100℃
Measurement accuracy
Current
±1.0%(10%Ie~120%Ie)
Leakage current
±1.0%(5%Ise~100%Ise)
Voltage
±0.5%(20%Ue~150%Ue)
 Frequency
±0.02Hz(45Hz~65Hz)
Power factor
±1.0%(-1~1)
Energy
±2.0%
Power
±2.0%
Communication
Communication interface
RS485,Photoelectric isolation interface
Communication protocol
Modbus-RTU,1200~38400bps
Profibus-DP,9600~12Mbps
Electrical insulation
Power frequency withstand voltage
AC2kVmin~1mA Input-output-power source
Insulation resistance
>50MΩ
Impact voltage
5kV(Peak),1.250us
Working environment
Operating temperature
-25℃ ~ +70℃
Relative humidity
5%~95% No condensation
Storage temperature
-30℃ ~ +75℃
1. Overload protection
2. Stall protection
3. Current imbalance protection
4. Start overtime protection
5. Ground protection
6. Phase failure protection
7. Contactor sectional current protection
8. Underload protection
9. Blocking protection
10. Leakage Protection
11.TE time protection
12.Overvoltage protection
13.Undervoltage protection
14.Under-power protection
15.Power factor protection
16.Undervoltage restart
17.Phase sequence protection
18.Temperature protection
19.External fault protection