Constant Laboratory Temperature And Humidity Test Climatic Box Constant Temperature Chamber
Negotiable
Min.Order:1
Uv 300W Lamp Anti Yellow Aging Test Chamber Yellowing Chamber Plastic Uva Uvb Aging Test Chamber
Uv Aging Anti-Yellow Tester Price Uva Uvb Uv Weather Resistence Climatic Test Chamber
Anti-Yellowing Aging Tester Manufacturer Direct Sale Anti-Yellow Uv Lamp Aging Testing Chamber
Automatic Plastic Melt Flow Index Tester MFI Testing Machine Melt Flow Indexer
Model | KJ-2091 | ||||||||
Inner size W×H×D(cm) | 40×50×40 50×50×60 70×70×85 100×80×100 | ||||||||
Inner chamber volume(V) | 80L 150L 225L 408L | ||||||||
Temperature and humidity Controll range | -40°C~150°C RH20%-98% | ||||||||
Function | Temperature and humidty fluctuation | ±0.5°C,±2.5%RH | |||||||
Temperature and humidity deviation | ±0.5°C-±2°C,±3%RH(>75%RH); ±5%RH(≤75%RH) | ||||||||
Controller resolution | ±0.3°C,±2.5%RH | ||||||||
Controller brand | Korea TEMI880 | ||||||||
Heating Time (RT-HT)°C/min | 100 | 150 | |||||||
40 | 50 | ||||||||
Cooling Time (RT-LT)°C/min | -20 | -40 | -60 | -70 | |||||
40 | 50 | 55 | 80 | ||||||
Power supply KW | 4.0 | 6.0 | 6.0 | 6.0 | |||||
Material | Inner material | SUS 304# steel plate | |||||||
Outside material | SUS 304# steel plate(surface disposing) | ||||||||
Thermal insulation material | Thermostability high density chlorine formic acid foam insulator material | ||||||||
System wind pathround-robin mode | centrifugal fan-broadband enforce circulation | ||||||||
Refrigeration way | Single stage compression refrigeration | ||||||||
Refrigerator | whole sealing piston France Taikang brand Compressor | ||||||||
Freezing fluid | R4O4A or USA Dupont environmental protection refrigerant(R23+R404) | ||||||||
Condensation way | forced air cooling or water-cooling | ||||||||
Heater | Nichrome heating wire heating | ||||||||
Humidifier | Semi-enclosed steam humidification | ||||||||
Water-provide way | full-automatic periodical feeding | ||||||||
Standard configuration | 1 Observe window(double-deck cavity toughened glass),1 50mm test hole in the left,1 PL inner chamber lamp,2clapboards, 1 bag of wet and dry bulb,3 fuses, 1 power line. | ||||||||
Safety device | Non- fuse-switch(compressor overload, refrigerant high low voltage,over-humidity and temperature protection,Protection switch,fuse stoppage warning system | ||||||||
Power | 1φ 220V AC±10% 50/60Hz 3φ 380V AC±10% 50/60Hz | ||||||||
Design Standard | GB/T2423/5170/10586, JIS C60068, ASTM D4714, CNS3625/12565/12566 |