Climate Humidity Conditioning Tabletop High Low Temperature Test Chamber
Negotiable
Min.Order:1
Simulated Environmental Temperature Humidity Climatic Test Chamber With Touch Screen Controller
Melt Flow Index Meter Melt Flow Index Equipment Xnr-400D Melt Flow Indexer
ISO Laboratory Testing Melt Flow Tester Index Digital Melt Flow Indexer Accessories
Industrial Plastic Melting Machines Melt Flow Tester Polyethylene Plastic Melt Index Meter
Electronic High Temperature Plastic Point Load Tester Melt Flow Rate Index Test Instrument
Price Plastic Melt Flow Index Tester Laboratory Mfr Mvr Melt Flow Indexer Price
Model | KJ-2091 | ||||||||
Inner size W×H×D(cm) | 40×50×40 50×50×60 70×70×85 100×80×100 | ||||||||
Inner chamber volume(V) | 80L 150L 225L 408L | ||||||||
Temperature and humidity Controll range | -40°C~150°C RH20%-98% | ||||||||
Function | Temperature and humidty fluctuation | ±0.5°C,±2.5%RH | |||||||
Temperature and humidity deviation | ±0.5°C-±2°C,±3%RH(>75%RH); ±5%RH(≤75%RH) | ||||||||
Controller resolution | ±0.3°C,±2.5%RH | ||||||||
Controller brand | Korea TEMI880 | ||||||||
Heating Time (RT-HT)°C/min | 100 | 150 | |||||||
40 | 50 | ||||||||
Cooling Time (RT-LT)°C/min | -20 | -40 | -60 | -70 | |||||
40 | 50 | 55 | 80 | ||||||
Power supply KW | 4.0 | 6.0 | 6.0 | 6.0 | |||||
Material | Inner material | SUS 304# steel plate | |||||||
Outside material | SUS 304# steel plate(surface disposing) | ||||||||
Thermal insulation material | Thermostability high density chlorine formic acid foam insulator material | ||||||||
System wind pathround-robin mode | centrifugal fan-broadband enforce circulation | ||||||||
Refrigeration way | Single stage compression refrigeration | ||||||||
Refrigerator | whole sealing piston France Taikang brand Compressor | ||||||||
Freezing fluid | R4O4A or USA Dupont environmental protection refrigerant(R23+R404) | ||||||||
Condensation way | forced air cooling or water-cooling | ||||||||
Heater | Nichrome heating wire heating | ||||||||
Humidifier | Semi-enclosed steam humidification | ||||||||
Water-provide way | full-automatic periodical feeding | ||||||||
Standard configuration | 1 Observe window(double-deck cavity toughened glass),1 50mm test hole in the left,1 PL inner chamber lamp,2clapboards, 1 bag of wet and dry bulb,3 fuses, 1 power line. | ||||||||
Safety device | Non- fuse-switch(compressor overload, refrigerant high low voltage,over-humidity and temperature protection,Protection switch,fuse stoppage warning system | ||||||||
Power | 1φ 220V AC±10% 50/60Hz 3φ 380V AC±10% 50/60Hz | ||||||||
Design Standard | GB/T2423/5170/10586, JIS C60068, ASTM D4714, CNS3625/12565/12566 |