Programmable Constant Temperature Humidity Test Cabinet Equipment Temperature Humidity Climatic Tester
Negotiable
Min.Order:1
High And Low Constant Temperature Humidity Test Chamber Temperature Test Chamber
High Low Temperature Test Chamber Humidity And Temperature Control Cabinets
Constant Electronic Temperature And Humidity Customized Test Chamber
Constant Laboratory Mini Benchtop Temperature And Humidity Test Chamber
Astm D1238 Melt Flow Indexer Price Melt Flow Index Testing Machine Melt Flow Tester
Digital Display Melt Flow Index Laboratory Testing Melt Flow Tester Index Digital Melt Flow Indexer
Model | KJ-2091 | ||||||||
Inner size W×H×D(cm) | 40×50×40 50×50×60 70×70×85 100×80×100 | ||||||||
Inner chamber volume(V) | 80L 150L 225L 408L | ||||||||
Temperature and humidity Controll range | -40°C~150°C RH20%-98% | ||||||||
Function | Temperature and humidty fluctuation | ±0.5°C,±2.5%RH | |||||||
Temperature and humidity deviation | ±0.5°C-±2°C,±3%RH(>75%RH); ±5%RH(≤75%RH) | ||||||||
Controller resolution | ±0.3°C,±2.5%RH | ||||||||
Controller brand | Korea TEMI880 | ||||||||
Heating Time (RT-HT)°C/min | 100 | 150 | |||||||
40 | 50 | ||||||||
Cooling Time (RT-LT)°C/min | -20 | -40 | -60 | -70 | |||||
40 | 50 | 55 | 80 | ||||||
Power supply KW | 4.0 | 6.0 | 6.0 | 6.0 | |||||
Material | Inner material | SUS 304# steel plate | |||||||
Outside material | SUS 304# steel plate(surface disposing) | ||||||||
Thermal insulation material | Thermostability high density chlorine formic acid foam insulator material | ||||||||
System wind pathround-robin mode | centrifugal fan-broadband enforce circulation | ||||||||
Refrigeration way | Single stage compression refrigeration | ||||||||
Refrigerator | whole sealing piston France Taikang brand Compressor | ||||||||
Freezing fluid | R4O4A or USA Dupont environmental protection refrigerant(R23+R404) | ||||||||
Condensation way | forced air cooling or water-cooling | ||||||||
Heater | Nichrome heating wire heating | ||||||||
Humidifier | Semi-enclosed steam humidification | ||||||||
Water-provide way | full-automatic periodical feeding | ||||||||
Standard configuration | 1 Observe window(double-deck cavity toughened glass),1 50mm test hole in the left,1 PL inner chamber lamp,2clapboards, 1 bag of wet and dry bulb,3 fuses, 1 power line. | ||||||||
Safety device | Non- fuse-switch(compressor overload, refrigerant high low voltage,over-humidity and temperature protection,Protection switch,fuse stoppage warning system | ||||||||
Power | 1φ 220V AC±10% 50/60Hz 3φ 380V AC±10% 50/60Hz | ||||||||
Design Standard | GB/T2423/5170/10586, JIS C60068, ASTM D4714, CNS3625/12565/12566 |