Manufacturer wholesale OEM & ODM circuit breaker Latest arrival Plug-in type installation MCB
Negotiable
Min.Order:1
Cheapest factory price dc circuit breaker Wholesale modern design circuit breaker safety
1P 2P 3P 4P AC230V/400V 4.5KA DZ47-63 Satety breaker with Cover Series Safety Breaker
DZ47-63 with cover 1P 2P 3P 4P 5A-40A 50A-63A AC230/240 High Quality Mini Circuit Breaker
BH with cover 2P 6A-40A 50A-60A 70A-100A AC230/240 Small overload circuit protection circuit breaker
DZ47LE-63Residual Series Miniature Circuit Breaker |
|
DZ47LE-63 is applicable to a line of AC 50Hz/60Hz, rated voltage 230V for single pole two-wire, 2-pole or 400V for 3-pole, 3-pole 4-wire, 4-pole and rated current up to 40A. It can protectthe line and motor from overload and short circuit. It can also be used for infrequent line conver-sion and infrequent motor start. It conforms with the standards of IEC61009. |
2.Main Technical Parameter |
Type | DZ47LE-63 | ||||||
Pole | 1P+N,2P | 3P,3P+N,4P | |||||
Rated current (A) | 6,10,16,20,25,32,40,50,63 | ||||||
Rated voltage (V) | 230 | 400 | |||||
Rated short circuit breaking capacity Icn(KA) | 6-32A :6 / 40-63: 4.5 | ||||||
Rated residual making/breaking capacity Im(A) | 2000 | ||||||
Rated residual action current In(A) | 0.03,0.05,0.1,0.3 | ||||||
Rated residual non-action current Ino(A) | 0.5In |
3. Applicable conducting wire |
Rated current(A) | 1-6A | 10A | 16,20A | 25A | 32A | 40,50A | 63A |
Norminal cross section of wire mm2 | 1 | 1.5 | 2.5 | 4 | 6 | 10 | 16 |
4.Residual current breaking time |
In(A) | In(A) | Breaking time(s) when equals to rating following | |||||
In | 2In | 5In | 5,10,20,50,100,200,500a(A) | Itb | |||
6-63 | 0.03, 0.05, 0.1, 0.3 | 0.1 | 0.06 | 0.04 | 0.04 | 0.04 |
5. The over-current protection property |
Ambient Temperature | Initial Status | Test Current | Expected Result | Expected Result | Note | ||
30±oC | Cold position | 1.13In | t≥1h | Non-release | - | ||
Carried out immediately after previous test | 1.45In | t< 1h | Release | - | |||
Cold position | 2.55In | 1s < T < 60S(IN≤32A) | Release | Current smoothly rises tospecified value within 5s | |||
Cold position | 2.55In | 1s < T < 120S(IN>32A) | Release | ||||
-5~+40oC | Cold position | 3In | t≥0.1s | Non-release | Type B | ||
Cold position | 5In | t<0.1s | Release | Type B | |||
Cold position | 5In | t ≥ 0.1s | Non-release | Type C | |||
Cold position | 10In | t < 0.1s | Release | Type C | |||
Cold position | 10In | t≥0.1s | Non-release | Type D | |||
Cold position | 20In | t<0.1s | Release | Type D |
6. Dimension |
Q1: Are you a circuit breaker factory or a circuit breaker from a trading company?
A1: We are a factory of circuit breaker.
Q2: Can samples be provided for free?
A2: Samples can be provided, but the sample cost should be paid by you. Sample fees will be refunded after further ordering.
Q3: Do you accept customized orders?
A3: Yes. We can provide OEM, ODM services.
A4: We accept TT, 30% deposit and 70% balance before give delivery.
Q5: When is the delivery time?
A5: It usually takes 15-25 days to confirm payment after LY, but the specific time should be based on the order quantity.
Q6: Tell me the standard of package?
A6: Export standard package or special package according to customer requirement.