dry well temperature calibrator
dry well temperature calibrator
dry well temperature calibrator
dry well temperature calibrator
dry well temperature calibrator

dry well temperature calibrator

1899 - 2099 /Piece

Min.Order:1 Piece

Supply Ability:
100 Piece / Pieces per Month
Port:
shanghai
Payment Terms:
T/T
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
East Tester
Place of Origin:
China
Model Number:
ET2501-150B
Temperature Range:
-30~150degree protable dry block temperature calibrator
Usage:
Industrial
Theory:
Temperature Recorder

hangzhou zhongchuang electron co.,ltd

Business license
Business Type: Manufacturer
Hangzhou Zhejiang China
Main Products: dry well block temperature ,dc load ,procss calibrator ,multimeter calibrator ,clamp calibrator

Product Details

Product features

 

This product is easy to carry, easy to use, fast and reliable temperature efficiency, widely used in machinery, chemical industry, food, medicine and other industries. The problem of slow temperature rise and slow temperature rise is common in the existing dry test furnace in China, which leads to a long time for users to calibrate each time. The latest generation of dry well furnace of our company adopts the most advanced heating principle design in the world. It has the characteristics of fast temperature rise, fast temperature rise and fast temperature drop, which greatly improves the existing calibration efficiency.

Through reliable high precision temperature control circuit and high precision sensor, the precision is higher than that of other domestic manufacturers, and the technology has reached international standards. The first worldwide touching operation, simple and fast to use.

   

Main features: Small size, light weight, easy to carry;

Various types of insertion tube, can meet the different size, quantity of sensor testing and

calibration. And can be customized according to the special needs of users;

Horizontal temperature and vertical temperature field;

Check the depth of insertion with the industry leader;

5.7 inch TFTLCD touch screen, 16 bit true color RGB display, full touch operation, intuitive

use;

Fast cooling, easy to set, good temperature stability;

Hot and fast replacement;

With load short circuit, load switch, sensor protection and other functions.

 

 

General technical specifications

 

lLanguage: Chinese, English;

lCommunication interface: USB Device (optional).

lThe ambient temperature range: 0~50℃(32-122℉);

lAmbient humidity range: 0%-90% (non condensing);

 

 

       model

 

ET2501-150A

 

ET2501-150B

ET2501-650

ET2501-1200

temperature range

-20℃~150℃

-30℃~150℃

50℃~650℃

300℃~1200℃

heating rate

 

30~100:20min

30~150:40min

30~100:20min

30~150:40min

30~300:7min

30-400:12min

30~650:25min

30~1200:75min

Display accuracy

≤±0.1℃

≤±0.1℃

Below 400≤±0.35℃

400-650℃≤±0.5℃

≤±1.2℃

Insertion depth

160mm

150mm

135mm

Average heat block diameter

36mm

32mm

32mm

39mm

Temperature field stability

≤±0.02℃

≤±0.02℃

≤±0.05℃

≤±0.2℃

Horizontal temperature field

≤±0.05℃

≤±0.05℃

≤±0.05℃

≤±0.25℃

Vertical temperature field

 The deviation in the range of 50mm calculated from the bottom of the hole of the soaking block is 1 degree

Temperature unit

℃ or ℉

Display resolution

0.01℃ or 0.1℃

0.01℃

0.01℃ or 0.1℃

0.01℃ or 0.1℃

maximum power

Negative temperature type: 500W, medium temperature type: 800W, high temperature type: 3000W

weight(Net weight)

Negative temperature type: 13kg, medium temperature type: 11kg, high temperature type: 11kg

weight (Containing packaging)

 

Negative temperature type: 23kg, medium temperature type: 18kg, high temperature type:20kg  Packaging includes aluminium box and transport wooden box

Outline size

 

Negative temperature type and high temperature type: 310*190*340mm, medium temperature type: 250*150*310mm

Use environment

Ambient temperature 0-50℃, relative humidity less than 95% (no condensation)

Power supply

220VAC ± 10%, 45 ~ 60Hz, optional 110VAC ± 10%.

Selection function

Verification Data Recording and Exporting (ET2501 only optional), up to 50 sensors, 600 records,USB Device Communication Interface

 

Other temperature ranges should be specified when ordering. The negative temperature type of -20℃~150℃ has 4 holes,are φ6/ 8/ 10/ 12 mm .The negative temperature type of     -30 ~150 has 4 holes,are 6/ 8/ 12 mm.The medium temperature type of  has 2 kinds (2 choices 1    at the time of ordering), one is 3 holes of 8/ 10/ 12mm, the other is 4 holes of 6mm*2, 8mm*2.The high temperature     type of 300 ~1200 has 4 holes, are 6/ 8/ 10/ 12mm.    Special specification aperture can be customized and should be specified when ordering.

 


Contact Supplier

Ms. kate liu seller Chat Now
Telephone
86-0571-56861356
Mobile
86-18767193418
Skype
18767193418
Address
gongshu Hangzhou,Zhejiang
Whatsapp
13958062364