STC-3000 LED Digital Thermostat for Incubator Temperature Controller Thermoregulator Heating Cooling 12V 24V 220V Fahrenheit
Negotiable
Min.Order:1
Description:
Switch the modes between cool and heat;
Control temperature by setting the temperature setting value and the difference value;
Temperature calibration;
Refrigerating control output delay protection;
Alarm when temperature exceeds temperature limit or when sensor error.
Specification
Front panel size: 75x34.5(mm)
Mounting size: 71x29(mm)
Product size: 75x34.5x85(mm)
Sensor length: 1 meter (include the probe)
Technical Parameters
Temperature measuring range: -50~99 Celsius
Accuracy: 0.1 Celsius
Sensor error delay: 1 minute
Power supply: DC 12V, DC 24V, 110V/220V AC+10%, 50/60Hz
Power consumption: <3w
Sensor: NTC sensor(IPC)
Relay contact capacity: Cool (10A/220VAC); Heat (10A/220VAC)
Ambient temperature: 0-60 Celsius
Storage temperature: -30-75 Celsius
Relative humidity: 20-85%(No condensate)
Indicator light status instruction
Indicator light |
Function |
Cool indicator light |
On:Refrigeration starts;Off:Refrigeration stops;Flash:compressor delay |
Heat indicator light |
On: heating starts;Off:heating stops |
Set indicator light |
On:parameter setting status |
After the completion, press and release the power button to save the parameter modification and return to the normal temperature display state.
If there is no key operation within 0 seconds, the parameter modification will not be saved and return to the normal display state.
“Er” is displayed if an error occurs while saving the parameter, and returns to the normal display state after 3 seconds.
3.Repair system data
When the machine is powered on, first check whether the parameter setting is normal. If the check is wrong, it will display “ER”. Pressing any key at this time will restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.
Operation instruction
Under controller normal working status, press and hold “ ” key for 3s can turn off the controller; Under controller “off” status, press and hold “ ” key for 3s can turn on the controller.
Under the controller normal working status, screen displays the current temperature value; also the controller can also switch the working mode between heating and cooling.
Controller starts refrigerating with cool indicator light on when the measuring temperature ≥ temperature set value + difference value, and the refrigerating relay is connected; The “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature ≤ temperature set value, the Cool indicator light on, and refrigerating relay disconnects.
System starts heating when the measuring temperature value ≤ the temperature set value-difference value, and the “Heat” indicator light on, and the heat relay connects; When the measuring temperature ≥ temperature set value, the “Heat” indicator light is off, and the heat relay disconnects.
Menu instruction
Code |
Function |
Set range |
Default |
F1 |
Temperature set value |
-50~99° |
10° |
F2 |
Difference set value |
1~10° |
3° |
F3 |
Compressor delay time |
1~10 minutes |
3 minutes |
F4 |
Temperature calibration value |
-10°~10° |
0° |
F5 |
Fahrenheit/Celsius switching |
Set range |
0/1
|
Error description
Alarm when sensor error: Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the running status is closed off with the buzzer alarms, and the nixie tube displays “EE”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
Alarm when the measuring temperature exceeds temperature measuring range:Controller activates the error alarm function when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer alarms, and the nixie tube displays “HH”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
Safety Regulations