Home using AC three phase data logger multimeter digital meter
Negotiable
Min.Order:1
Jiangsu Sfere Electric Co., Ltd.
Energy monitor system multifunction power meter lcd display multimeter
PS195P-5SY1 96*48mm single phase mini digital LCD display dc active power meter modbus
PD195E-5KY1 96*48mm lcd display digital dc modbus ampere meter
Elecnova PD195E-5KY1 96*48mm 1 phase lcd panel digital RS485 dc ampere energy meter
PS195P-5SY1 96*48mm 1 phase LCD dc electric active power meter with relay output
PS195P-5SY1 96*48mm single phase digital LCD display dc kW meter
Accuracy | Voltage and current | 0.2% | ||||
Power,Power Factor | 0.2% | |||||
Frequency | ±0.01Hz | |||||
Active power | IEC62053-22/IEC61557-12, class 0.2S | |||||
Reactive power | IEC62053-23, class 2 | |||||
Data update rate | 1s | |||||
Input | Wiring mode | 1P2W、3P3W、3P4W | ||||
Voltage | Rated value | 400 VAC L-N (690 VAC L-L) | ||||
Overload | 1.2Vln | |||||
Impedance | >1MΩ | |||||
Current | Rated value | 1A or 5A | ||||
Overload | Continuous: 1.2In | |||||
Instantaneous: 10In/5s | ||||||
burden | <0.1VA | |||||
Rated value | <20mΩ | |||||
Grid frequency | (45~65)Hz | |||||
Auxiliary supply | Working range | AC/DC(80~270)V | ||||
consumption | ≤ 10VA | |||||
Energy pulse output | 1 photocouple outputs, pulse width (80±20%) ms | |||||
Digital input | AC220V input, isolation:2000VAC | |||||
Relay output | Contact rated at AC 250V/5A or DC 30V/5A | |||||
Isolation: 2500VAC | ||||||
Communications | ||||||
RS485 port | Modbus-RTU , 2-wire,up to 38400bps | |||||
Mechanical Characteristics | ||||||
IP index | IP65(front panel)and IP20(meter body) | |||||
Dimensions | 96×96×55mm | |||||
Environmental Characteristics | ||||||
Operating temperature | (-10~60)℃ | |||||
Storage temperature | (-25~70)℃ | |||||
Relative humidity | (5~95)% (no gel) | |||||
Insulation | IEC 61010-1 | |||||
Electromagnetic Compatibility | ||||||
Immunity to electrostatic discharge | IEC 61000-4-2-Level III | |||||
Immunity to radio-frequency field | IEC 61000-4-3- Level III | |||||
Immunity to electrical fast transients/bursts | IEC 61000-4-4- Level Ⅳ | |||||
Immunity to impulse waves | IEC 61000-4-5- Level Ⅳ | |||||
Immunity to conducted disturbances | IEC 61000-4-6- Level III | |||||
Immunity to power frequency magnetic fields | IEC 61000-4-8- Level III | |||||
Immunity to voltage dips and short interruptions | IEC 61000-4-11- Level III | |||||
Module | ||||||
FM1 | 2 AC digital input | |||||
FM2 | 4 digital inputs | |||||
FM3 | 2 relay outputs | |||||
FM4 | 2 analog inputs:mA | |||||
FM5 | 2 analog inputs:PT100 | |||||
FM6 | 2 analog outputs:mA | |||||
FM7 | RJ45, Modbus/TCP | |||||
FM8 | DB9, Profibus-DP | |||||
FM9 | WIFI: Modbus/TCP | |||||
FM10 | GPRS: Modbus/TCP, SMS | |||||
FM11 | RS485, Modbus-RTU | |||||
FM12 | M-Bus communication | |||||
FM13 | BACnet/MSTP communication | |||||
FM14 | BACnet/IP communication | |||||
FM15 | RS232, Modbus-RTU |