Hige Permeate Material Moisture Test Water Vapor Permeability Testing Machine
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Composite Membrane Adhesion Performance Test Peeling Testing Machine High Temperature
Gurley Standard Air Permeability Tester Battery Separator Performance Test
Max Gas Permeability Testing Equipment For New Material Research GC
High-Oxygen Modified Atmosphere Packaging Lab Tester Oxygen Permeability Testing Machine
New Update Air Bath Heating Film Shrinkage Tester Lab Shrink Testing Machine
Hige Permeate Material Moisture Test Water Vapor Permeability Testing Machine
Products Catalog
What we can provide
Packing
About Quality
Product Details
Application:
Based on the humidity sensor detection method and available for the water vapor permeability test of heat exchange membranes, nonwoven fabrics and flexible barrier materials.
Hige Permeate Material Moisture Test Water Vapor Permeability Testing Machine
Features:
features | Weighing method |
Dual weighing modules, own technology | |
18 specimens, continuously test | |
One-button test, test automatically in whole process | |
Multiple test modes optional | |
Temperature and humidity auto control | |
Data curves display | |
Computer control | |
Environment temperature and humidity sensor inside | |
Unit based on embedded system,24bit Δ-Σ AD | |
Traceable reference film calibration | |
Supports DSM system (DSM, lab data management system) |
Principles:
The specimen is clamped between the upper and lower chamber, the upper chamber is high humidity side, and the other side of specimen, lower chamber is purged by a stream of dry gas, due to the effect of water concentration gradient at two sides of the specimen, water molecules will permeate through the specimen into the dry gas side, penetrated water molecules will be carried to the relative humidity sensor which generates the proportional signal, so water vapor transmission rate will be obtained by calculating the sensor signal.
Hige Permeate Material Moisture Test Water Vapor Permeability Testing Machine
Technical indexes:
Test range | 5 - 6500 g/m2·24h (Standard) |
Resolution | 0.001 g/m2·24h |
Specimen amount | 1 specimen |
Temperature range | 5C–95C |
Temperature accuracy | ±0.1C |
Humidity range | 100%RH (Standard) |
Humidity accuracy | ±1%RH |
Test area | 38 cm2 (Standard) |
Specimen size | >=150mm * 94mm |
Thickness | less 3mm |
Carrier gas | Dry Air, or 99.999% Nitrogen |
Carrier flow | 0~200 ml/min |
Gas interface | 1/8inch |
Power supply | AC 220V 50Hz |
Dimension | 330mm(L) * 600mm(D) * 330mm(W) |
Net weight | 30kg |