Air Resistance Of Paper Gurley Method Air Permeability Testing Equipment
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
ASTM Standard Working Procedure Of Water Vapor Permeability Tester
Weighing Method For Fabric Material/ BOPP Water Vapor Permeability Testing Equipment
Hot Tack Testing Equipment Astm F1921 Plastic Membrane Lab Test
ASTM Standard Dynamic & Static Friction Test Coefficient Of Friction Testing Machine COF
Oxygen Permeability Testing Machine OTR For Atmosphere Modified Packages
Beverage Intergated Sealing Test Vacuum Leakage Testing Machine Leak Bubble Method
Air Resistance Of Paper Gurley Method Air Permeability Testing Equipment
Product Detail
Application:
Based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Air Resistance Of Paper Gurley Method Air Permeability Testing Equipment
Features:
Ÿ Vacuum differential pressure method
Ÿ Own technology
Ÿ 3 specimens test simultaneously and independently
Ÿ Computer control
Ÿ One-button test, test automatically through whole process
Ÿ High accuracy vacuum sensors embedded in
Ÿ 3 Chambers with independent temperature sensor
Ÿ Test under various RH conditions with Humidity generator (optional)
Ÿ Environment temperature and humidity sensor inside
Ÿ Permeability coefficient ,solubility coefficient and diffusion coefficient test
Ÿ Chambers with water bath temperature control technology
Ÿ Unit based on embedded system,24bit Δ-Σ AD
Ÿ Multiple test modes optional
Ÿ Data curves display
Ÿ Traceable reference film calibration
Ÿ Supports DSM system (DSM, lab data management system)
Air Resistance Of Paper Gurley Method Air Permeability Testing Equipment
Technical Indexes:
Test range | 0.01 - 190,000 cm3/m2·24h·0.1MPa (Standard) |
Resolution | 0.001cm3/m2·24h·0.1MPa |
Samples | 3, independent |
Vacuum accuracy | 0.1Pa |
Temperature range | 5C - 95C |
Temperature accuracy | ±0.1C |
Humidity range | 0%RH,35%RH-90%RH,100%RH (optional) |
Humidity accuracy | ±1%RH (optional) |
Sample thickness | less 5mm |
Sample size | >= 150mm * 94mm |
Test area | 48cm2 |
Test gas | O2, N2, CO2, He, etc |
Differential pressure | -0.1MPa - 0.1MPa |
Gas interface | Ф8mm |
Products Catalog
What we cab provide
Packages & Logistics
Export Areas
Contact