TKZHSF6 Comprehensive Analyzer
Negotiable /Piece
Min.Order:1 Piece
Wuhan Guodian Mingke Electric Co., Ltd.
SF6 comprehensive tester is a collection of sf6 micrometer sf6 purity tester sf6 decomposition product analyzer in one concentrate the functions of three instruments in one instrument. One on-site measurement can complete the detection of three indicators greatly saving gas in the equipment. One measurement can save 2/3 gas consumption reduce the workload of users and improve the work efficiency.
Product nickname:SF6 comprehensive tester fully automatic SF6 comprehensive tester automatic SF6 comprehensive tester
Purity | range of measurement :0%~100% | |
measurement precision:±0.5% | ||
measurement time: <2 minute | ||
Dew point | range of measurement :-80℃~+20℃ | |
measurement precision:±1℃(-80℃~-60℃) | ||
response time(-60℃~+20℃):63% need 5 second,90% need 45 second; | ||
response time(+20℃~-60℃):63% need 10 second,90% need 240 second | ||
H2S | range of measurement :0~200ppm | |
minimum amount of detector:≤0.1ppm | ||
degree of exactitude:±0.5% | ||
stability:0~200ppm | ||
repeat ability:≤2% | ||
SO2 | range of measurement :0~200ppm | |
minimum amount of detector:≤0.1ppm | ||
degree of exactitude:±0.5% | ||
stability:0~200ppm | ||
repeat ability:≤2% | ||
HF(optional) | range of measurement :0~20ppm | |
minimum amount of detector:≤0.01ppm | ||
degree of exactitude:±0.5% | ||
stability:0~20ppm | ||
repeat ability:≤2% | ||
CO(optional) | range of measurement :0~1000ppm | |
minimum amount of detector:≤1ppm | ||
degree of exactitude:±0.5% | ||
stability:0~1000ppm | ||
repeat ability:≤2% | ||
Environment temperature | -40℃~+60℃ | |
ambient humidity | 0~100%RH | |
Power supply | AC 220V | |
Integrated rechargeable battery | ||
Battery performance | charging time:20 hours;use time:10 hours abouve | |
Weight | 5 kg | |
Size | 250×150×300mm3 | |
operating temperature | -40℃~+80℃ |
Purity | range of measurement :0%~100% | |
measurement precision:±0.5% | ||
measurement time: <2 minute | ||
Dew point | range of measurement :-80℃~+20℃ | |
measurement precision:±1℃(-80℃~-60℃) | ||
response time(-60℃~+20℃):63% need 5 second,90% need 45 second; | ||
response time(+20℃~-60℃):63% need 10 second,90% need 240 second | ||
H2S | range of measurement :0~200ppm | |
minimum amount of detector:≤0.1ppm | ||
degree of exactitude:±0.5% | ||
stability:0~200ppm | ||
repeat ability:≤2% | ||
SO2 | range of measurement :0~200ppm | |
minimum amount of detector:≤0.1ppm | ||
degree of exactitude:±0.5% | ||
stability:0~200ppm | ||
repeat ability:≤2% | ||
HF(optional) | range of measurement :0~20ppm | |
minimum amount of detector:≤0.01ppm | ||
degree of exactitude:±0.5% | ||
stability:0~20ppm | ||
repeat ability:≤2% | ||
CO(optional) | range of measurement :0~1000ppm | |
minimum amount of detector:≤1ppm | ||
degree of exactitude:±0.5% | ||
stability:0~1000ppm | ||
repeat ability:≤2% | ||
Environment temperature | -40℃~+60℃ | |
ambient humidity | 0~100%RH | |
Power supply | AC 220V | |
Integrated rechargeable battery | ||
Battery performance | charging time:20 hours;use time:10 hours abouve | |
Weight | 5 kg | |
Size | 250×150×300mm3 | |
operating temperature | -40℃~+80℃ |