ICP Emission Spectrometer for Steel (ICP-AES)
USD $39,000 - $46,000 /Set
Min.Order:1 Set
Wuxi Jinyibo Instrument Technology Co., Ltd.
TY-9900 Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES)
Unbeatable Sensitivity and Extreme Precision for All elements
Specification
Simultaneous ICP-AES for elemental analysis of liquids
Wavelength range:195-800nm
For 70 trace elements and macroelements
Analyze up to 600 samples per day
Low operating costs
Intuitive operation
Ultra-low limits of detection
Ultra-high speed of measurement
Summary
TY-9900 Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) is developed based on both the tradition of inductively coupled plasma atomic emission spectroscopy technique and the absorption of the latest technological achievements of international research. The series are high-precision, high sensitivity, high stability, high test speed and wide measure range. The instrument consists of a scanning beam splitter, the RF generator, sample introduction systems, photovoltaic conversion, control systems, data processing systems, analysis and operating software. It is ideal for analytical instruments in many industries.
Applications
TY-9900 Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) can be applied in sample analysis of machinery, steel, geology, metallurgy, rare earth and magnetic materials, environment, medicine and health, biological, marine, petroleum, chemical new materials, nuclear industry, agriculture, food commodity inspection, water quality and other fields and disciplines. It can quickly and accurately detect about 70 kinds of elements from microelements to macro elements.
Parameter
Item | Index |
Machine technical indicators | |
Analyze speed | More than 15 elements can be scanned within 60s |
Scanning range | 3600/mm, scanning range:180~500nm, full band resolution<0.007nm. 2400/mm scanning range 180~900nm, full band resolution≤0.008nm. The mode: Sinusoidal rod. Control by computer, minimum scanning step:0.0003nm |
Wavelength indication error and repeatability | Wavelength indication:≤± 0.02nm repeatability≤ 0.003nm |
Correlation coefficient | ≥0.9998% |
Precision | RSD≤1.5% |
Stability | RSD≤2.0% |
Measuring range | Ultra trace to constant |
Low detection limit | ppb(ug/L)level |
Analysis of many elements | Can analyze 70 metal element and part of non-metallic elements(such as B, P, Si, Se, Te) |
Measurement method | Element order measurement |
Power | 750W—1600W automatic control |
RF generator | |
Working frequency | 40.68MHz |
Frequency stability | ≤0.1% |
Output power | 750—1600W |
Output power stability | ≤0.1% |
Injection device | |
Output work coil | Inside diameter: 25mm, 3 turns |
Torch tube | Three concentric type, outer diameter:20mm |
Coaxial sprayer outside diameter | 6mm |
Binocular fog chamber diameter | 34mm |
Monochromator | |
Light path | Czerny-Turner type |
Focal length | 1000mm |
Line Dispersion Countdown | 0.26nm |
Resolution | <0.007nm Choose 3600 r / mm grating |
Scan the wavelength range | 3600 line/mm, 180—500nm 2400 line/mm, 180—900nm |
Stepper motor drives the smallest step | 0.0003nm |
Exit, incident slit | 20μm,25μm |
Reflector specifications | (80×110×16)mm |
Lens | φ30, 1:1 imaging |
Reflector specifications | Concave |
Metering device | |
Photomultiplier tube negative pressure | 0—1000V automatic adjustable, stability<0.03% |
Photomultiplier tube current measurement range | 10-4~10-9A |
Signal acquisition for the V/F exchange | 1mV correspond 100Hz |
Metering method | Single multi-element sequential measurement |