Cheap Price AA4530F Lab AAS Atomic Absorption Spectrophotometer

Cheap Price AA4530F Lab AAS Atomic Absorption Spectrophotometer

USD $6,000 - $15,000 /Piece

Min.Order:1 Piece

Supply Ability:
300 Piece / Pieces per Month
Port:
Chongqing/Shanghai/Guangzhou/Shenzhen/Xiamen
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Drawell
Place of Origin:
Chongqing, China
Model Number:
DW-AA4530F
Size:
550mm*450mm*300mm
Weight:
65KG
Wavelength Range:
190-900nm

Chongqing Drawell Instrument Co., Ltd.

Business Type: Buying Office
Main Products: Mass Spectrometer ,Sterilizer

Product Details

DW-AA4530F Atomic Absorption Spectrophotometer

 

CHARACTERISTICS
1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).
2. Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.
3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize
the working condition of the hollow cathode lamp.
4. Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.
5. Fully automated wavelength scanning and peak searching.
6. Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout.
7. Deuterium lamp and self-absorption background regulation.
8. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
9. Measuring method: flame absorption method and emission method.
10.Result printing: parameter printing, data result printing and diagram printing.
 

COMPLETE AUTOMATIC CONTROLLING SYSTEM
With the help of the software, the following can be easily achieved
1. Selection of the element lamp
2. Up-down-front-rear adjustment of the lifter
3. Adjustment of the optical energy
4. Selection of the slit
5. Determination of wavelength scanning and peak searching
6.  Selection of the atomizer
7. Setting of the background deduction method
8.  Controlling of the gas flow
9. Automatic flaming and flaming out
10.Setting of the graphite furnace testing method

 

ADVANCED GRAPHITE FURNACE TEMPERA-TURE CONTROLLING TECHNOLOGY
1.The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process. The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data
2.The fast heating capacity can improve the flexibility of the elements further
3.Use the ordinary power source of 220V without need of dynamic power of 380V
4.The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples
5.Three grades adjustable gas flow can accustom to more application needs

 

AA4530F Atomic Absorption Spectrophotometer

SPECIFICATIONS

Wavelength range 

190 – 900nm

Spectral bandwidth

0.1, 0.2, 0.4, 1.0 and 2.0nm

Accuracy of the wavelength

±0.15nm

Receptivity of the wavelength 

≤0.04nm

Base line stability

≤0.002A/30min (Cu)

Characteristic viscosity

0.02μg/ml/1% (Cu)

Checking limit

0.004μg/ml (Cu)

Preciseness

0.5%

Grating

1800 lines/mm

Inflamer

All-metal titanium burner

Atomizer 

Effective glass atomizer

Lamp stand

8

D2 background correction ability

When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method

Size and weight

700mm×550mm×450mm  75Kg

Power source

220V±22V AC

FLAME SYSTEM

Acetylene air burner

100mm

Ignition dynamic baseline drift

≤0.006A/30min

(Cu) Characteristic viscosity

≤0.025μg/ml/1%

Related standard deviation of the accuracy

≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)

Safety system

Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

GRAPHITE FURNACE

The highest temperature

3000℃

The largest temperature rising speed

≥2000℃/S

Characteristic quantity

Cd≤0.5×10-12g  Cu≤0.5×10-11g

Accuracy

Cu≤3% Cd≤3%

Size and weight

550mm×450mm×300mm  65Kg

Safety system

Over current protection Low air pressure alarm / protection
Low cooling water flow alarm/protection

Power source and power

220V±22V  AC  7000W

STANDARD ACCESSORIES

PC workstation

HP inkjet printer

Oil free Air compressor 

Acetylene reducing valve 

Cu Hollow cathode lamp

Air filter

 Cheap Price AA4530F Lab AAS Atomic Absorption SpectrophotometerCheap Price AA4530F Lab AAS Atomic Absorption SpectrophotometerCheap Price AA4530F Lab AAS Atomic Absorption Spectrophotometer