Atomic Absorption Apectrophotometer (AAS) Price

Atomic Absorption Apectrophotometer (AAS) Price

USD $5,000 - $15,000 /Piece

Min.Order:1 Piece

Supply Ability:
100 Piece / Pieces per Month
Port:
Shanghai
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Drawell
Place of Origin:
Shanghai, China
Model Number:
DW-AA4530F
Size:
85*70*75cm / 117*67*92cm
Weight:
105kg/100kg
Wavelength Range:
190-900

Chongqing Drawell Instrument Co., Ltd.

Business Type: Buying Office
Main Products: Mass Spectrometer ,Sterilizer

Product Details

Atomic Absorption Spectrophotometer

DW-AA4530F

 

CHARACTERISTICS

1. Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

2. Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term.

3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize

the working condition of the hollow cathode lamp.

4. Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.

5. Fully automated wavelength scanning and peak searching.

6. Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout.

7. Deuterium lamp and self-absorption background regulation.

8. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.

9. Measuring method: flame absorption method and emission method.

10.Result printing: parameter printing, data result printing and diagram printing.

 

COMPLETE AUTOMATIC CONTROLLING SYSTEM With the help of the software, the following can be easily achieved

1. Selection of the element lamp

2. Up-down-front-rear adjustment of the lifter

3. Adjustment of the optical energy

4. Selection of the slit

5. Determination of wavelength scanning and peak searching

6.  Selection of the atomizer

7. Setting of the background deduction method

8.  Controlling of the gas flow

9. Automatic flaming and flaming out

10.Setting of the graphite furnace testing method

 

ADVANCED GRAPHITE FURNACE TEMPERATURE CONTROL TECHNOLOGY

The bringing in of PID technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process. The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data

The fast heating capacity can improve the flexibility of the elements further

Use the ordinary power source of 220V without need of dynamic power of 380V

The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples

Three grades adjustable gas flow can accustom to more application needs

Can  timely  alarm  when  the  gas  and  water  is

stopped and insufficient gas and water, can avoid the equipment damage and measuring error

 

SAFE,  RELIABLE AND  CONVENIENT FLAME SYSTEM

EPC can control the flow of Acetylene (C2H2) more accurately and it is a kind of system which also can operate easily

Efficient a tomi zati on s ys tem enables a higher sensitivity

The whole operation system has a high security as the fire safety system can alarm whenever the electrici- ty is cut off, abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off the gas, prohibit temper ing. Thus it keeps the operation people and equipment from harm and damage.

 

MULTI-FUNCTIONAL SOFTWARE WORKSTATION

A w o r k s t a t i o n t h a t i s s u p p o r t e d W I N D OW S XP/20 00/NT

The rich menu brings great convenience to the use of customer

Convenient conversion between different menus makes the operation more easily

Various analytical correction methods provide the

users more choices

Basic default parameter settings enable even the beginners can do the normal operation

Flexible sto r age, e ditin g and p rin tin g m e th ods give the user largest support

 

Specifications

Wavelength range    190 – 900nm

Spectral bandwidth   0.1, 0.2, 0.4, 1.0 and 2.0nm

Accuracy of the wavelength  ±0.15nm

Receptivity of the wavelength    ≤0.04nm

Base line stability     ≤0.002A/30min (Cu)

Characteristic viscosity     0.02μg/ml/1% (Cu)

Checking limit       0.004μg/ml (Cu)

Preciseness         0.5%

Grating               1800 lines/mm

Inflamer         All-metal titanium burner

Atomizer      Effective glass atomizer

Lamp stand     8

 

Flame System

Acetylene air burner: 100mm

Ignition dynamic baseline drift : 0.006A/30min

(Cu) Characteristic viscosity:   0.025μg/ml/1%

Related standard deviation of the accuracy : 

0.5%(Cu, absorbance>0.8A) (detection limit Cu0.008μg/ml)

Safety system:

Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

 

GRAPHITE FURNACE

The highest temperature:   3000

The largest temperature rising speed:    ≥2000/S

Characteristic quantity Cd≤0.5×10-12g  Cu≤0.5×10-11g

Accuracy:   Cu≤3% Cd3%

Safety system: Over current protection Low air pressure alarm / protection Low cooling water flow alarm/protection

Power source and power:  220V±22V  AC  7000W