Laboratory portable raman spectrometer price
Laboratory portable raman spectrometer price
Laboratory portable raman spectrometer price
Laboratory portable raman spectrometer price
Laboratory portable raman spectrometer price
Laboratory portable raman spectrometer price

Laboratory portable raman spectrometer price

USD $18,000 - $23,900 /Piece

Min.Order:1 Piece

Supply Ability:
500 Piece / Pieces per Month
Port:
Shanghai
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Drawell
Place of Origin:
Shanghai, China
Model Number:
DTR3010
Size:
30*22.5*13.2 cm3
Weight:
7.5 Kg, 7.5 Kg
Measurement Range:
200-1100

Shanghai Drawell Scientific Instrument Co., Ltd.

Business Type: Association
Main Products: Spectrophotometer ,Environmental Analyser

Product Details

Portable Cooled Raman Spectrometer

DTR3010

FEATURES

Ø Ultra-high sensitive FFT-CCD with TEC cooling;

Ø Ultra-low noise circuit;

Ø Powerful embedded software;

Ø Fluorescent background eliminate;

Ø Peak searching and indicating;

Ø 10.1’’ LCD;

Ø Android 4.0 OS;

Ø USB 2.0;

Ø Touch operation;

Ø Friendly HMI;

Ø Battery Endurance > 3 hours;

Ø Remote control via LAN;

Ø IP67 case;

APPLICATIONS

Ø Biological science

Ø Pharmaceutical engineering

Ø Forensic analysis

Ø Agriculture and food safety

Ø Gemstone

Ø Environmental science

 

GENERAL DESCRIPTION

DTR3010 portable Raman spectrometer is suitable for field operation. The outstanding reliability makes the detection result much accurate. The excellent low stray light conditions that enable the spectrometer has a wide range of application, especially in the biochemical analyzer, food safety, pharmaceutical engineering. The multi-function software facilitated the spectral analysis process in application. The remote experiment through internet access makes the bald test item much easier.

 

Specifications

DTR3010 System

Interface

USB 2.0/LAN

OS

Android 4.4.2

Battery endurance

>3 h

Integration time

4ms - 120s

Supply voltage

DC 19V(+/-5%)

Operating temperature

5~40 ℃

Operating humidity

< 95%

Size (L*W*H)

30×22.5×13.2 cm3

Weight

7.5 Kg

Reliability

Spectral stability

σ/μ < 0.5%  (COT 8 hours)

Temperature stability

Spectral shift ≤ 1 cm-1 (10-40 ℃)

Variation of Spectral intensity in 5 ~ 40 ℃

<±5%

Optics Parameter

Spectral region

250-2400 cm-1

Spectral resolution

2 cm-1@900nm

Signal-to-Noise

>3000:1 (918 cm-1 of Acetonitrile,10s accumulation, 200mW)

Incidence slit

50 μm

Optical system

f/4 Crossed Symmetrical Czerny-Turner

Focal length

98 mm for incidence and output

Detector

Type

Ultra-high sensitive FFT-CCD with TEC cooling

Detectable range

200-1100 nm

Effective pixel

2048*64

Dynamic range

50000:1

Pixel dimension

14μm×14μm

Full well capacity

300 Ke-

Sensitivity

QE>40%, 6.5 μV/e-

Exciting Laser

Center Wavelength

785nm (±0.5nm)

FWHM

0.08 nm

Output power

≥500 mW

Power stability

σ/μ <±0.2%

Raman Probe

Working distance

6 mm

Rayleigh scattering resistance

OD>8

Numerical Aperture

0.3

Aperture

7mm

 

Optical Performance

2.1 General spectral performance

Figure 1 Raman spectra of acetonitrile

 

Excited laser intensity: 200 mW

Integrate time: 5 s

Boxes car: 3 times

 

Spectral range: 250-2400 cm-1

918 cm-1 FWHM: 9 cm-1

918 cm-1 intensity: 28886 count

Noise: 89 count

S/N: 324

 

Figure 2 Sensitive of DTR3010 vs DTR2000

Figure 3 Noise of DTR3010 vs DTR2000

2.2 Spectral Resolution

2.2.1 Raman spectral of Tylenol

Fig.2.2 Raman spectrum of Tylenol,the vibration mode 1610/1615 cm-1 can be resolved.

 

Excited laser intensity: 200 mW

Integrate time: 10 s

Boxes car: 1 time

Raman spectra of Tylenol showed the resolution condition in the long wavelength region. That is better than 6 cm-1.

2.2.2 Raman spectral of petrol

Fig.2.3 Raman spectrum of petrol 93#, the vibration mode 723/732/742cm-1 can be resolved.

 

Excited laser intensity: 200 mW

Integrate time: 10 s

Boxes car: 1 time

 

Raman spectra of petrol 93# showed the resolution condition in the short wavelength region.

Reliability

    Figure 3.1 and Figure 3.2 showed the temperature reliability testing results of fives DTR3010 portable Raman spectrometers. The testing temperature range was from 5 oC to 40 oC. The spectrometer was kept more than 1 hour at every temperature spots. Acetonitrile was used as the standard sample in the testing. The testing results were calculated using 918 cm-1 of acetonitrile. The wavenumber shift was 1 cm-1 or less(as show in Fig. 3.1). The peak intensity variation was less than 10% (as show in Fig. 4).

Fig. 3.1 Wavenumber shift results testing from 5 oC to 40 oC of fives DTR3010 portable Raman spectrometers

Temperature range: 5-40 centigrade

Wavenumber shift: < 1 cm-1

Figure 4 Intensity variation testing from 5 oC to 40 oC of three DTR3010 portable Raman spectrometers

Figure 5 Intensity variation -10 oC to 40 oC of DTR3010 portable Raman spectrometers, sample is alcohol.

 

 

Product display

Laboratory portable raman spectrometer price 

case

Laboratory portable raman spectrometer price 

contacts

 

FAQ

 

payment methods

 

packing

 

exhibition

 

company profile

 

 

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Optical Instruments > Spectrometers
Categories
Hi~