FTIR-530A fourier transform infrared spectroscopy

FTIR-530A fourier transform infrared spectroscopy

USD $7,750 - $20,000 /Piece

Min.Order:1 Piece

Supply Ability:
100 Piece / Pieces per Month
Port:
Shanghai
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
DRAWELL
Place of Origin:
Shanghai, China
Model Number:
FTIR-530A
Size:
520 x 435 x 255mm, 24kg
Weight:
24kg
Wavelength Range:
7800cm-1~350cm-1

Shanghai Drawell Scientific Instrument Co., Ltd.

Business Type: Association
Main Products: Spectrophotometer ,Environmental Analyser

Product Details

Product Description

 

DW-FTIR-530  FT-IR SPECTROMETER

 

FTIR Spectrometer DW-FTIR-530 with fully independent intellectual property rights.  Adhering to consistent excellent quality and superior performance, the new model obtains the best balance between intelligence and convenient operation, advance performance and low operation and maintenance cost.  It is a good choice for basic science research analysis, production quality control,testing and detection in various fields.

 

High sensitivity and stability

Intelligent real-time monitoring of instrument status 

Multiple communication options

Flexible and convenient testing

Powerful software workstation

 

 

 

 

Features

High sensitivity optical system: cube-corner Michelson interferometer combined with patented fixing mirror alignment technology(Utility model ZL 2013 2 0099730.2:fixing mirror alignment assembly),to ensure long term stability, without the need of dynamic alignment which needs extra complicated electronic circuits.  Reflecting mirrors are coated with gold to provide the maximum light throughput and ensure the detection sensitivity.

High stability modular partition design: compact structure modular design with layout on cast aluminum base and overall balance of mechanical robustness and partition heat dissipation, offering higher ability of deformation resistance and less sensitive to vibrations and thermal variations, greatly improves the mechanical stability and long term working stability of the instrument.

Intelligent multi-sealed moisture-proof design: multiple sealed interferometer, large-capacity desiccant cartridge with visible window and easy replacement structure, real-time monitoring of temperature and humidity inside the interferometer, getting rid of influences of high temperature, high humidity and chemical corrosions to the optical system in many ways.

Innovated integration electronic system:  high sensitivity integrated DLATGS detector pre-amplifier technology, dynamic gain amplification technology, high precision 24-bit A/D conversion technology, real-time control and data processing technology, digital filter and network communication technology, ensuring high quality real-time data collection and high-speed transmission.

Good anti-electromagnetic interference capability: The electronic system is designed to meet CE certification and electromagnetic compatibility requirements, minimizing electromagnetic radiation in design and technology,in line with green instrument designing concept.  

High intensity IR source assembly: High intensity, long lifetime IR source module, with the highest energy distributed in fingerprint region, adopts a reflex sphere design to obtain even and stable IR radiation.  External isolated IR source module and large space heat dissipation chamber design provide higher thermal stability and stable optical interference.

The sampling compartment, reserving accessory mounting holes on the base plate, is wide enough for various accessories such as Defused/Specular Reflection, ATR, Liquid cell, Gas cell, and IR microscope etc.


Specifications:

 

Interferometer

Cube-corner Michelson interferometer

 

Beam splitter

Multilayer Ge coated KBr

 

Detector

Room temperature DLATGS module (standard)

Temperature stabilized, high sensitivity DLATGS module (optional)

IR Source

High intensity, long lifetime, air-cooled IR source

 

Wavenumber Range

7800cm-1~350cm-1

 

Resolution

0.85 cm-1

 

Signal to noise ratio

Better than 20,000:1 (RMS value, at 2100cm-1 ~ 2000cm-1 or 2100cm-1 ~ 2200cm-1, resolution: 4cm-1, detector: DLATGS, 1 minute data collection)

 

Wavenumber Accuracy

±0.01 cm-1

 

Scanning Speed

Microprocessor control, different scanning speed selectable.

 

Software

MainFTOS Suite software workstation, compatible to all version Windows OS

Various specialized functional software modules (optional) 

Communication

Ethernet interface (standard)

WIFI wireless communication (optional)

Data Output

Standard data format, report generation and output

 

Status Diagnosis

Power on self check, real-time temperature and humidity monitoring and reminders

 

Certification

 

FDA 21 CFR Part11 compliance,IQ/OQ/PQ(Optional)

Environment Conditions

Temperature: 10~30,

humidity: less than 70%

 

Power Supply

AC220V±22V,50Hz±1Hz

AC110V(optional)

Dimensions & Weight

520 x 435 x 255mm, 24kg

 

Accessories

Transmission sample holder (Standard)

Optional accessories such as gas cell, liquid cell, Defused/Specular Reflection, single/multi reflection ATR, etc. 

 

 

 FTIR-530A fourier transform infrared spectroscopyFTIR-530A fourier transform infrared spectroscopyFTIR-530A fourier transform infrared spectroscopyFTIR-530A fourier transform infrared spectroscopyFTIR-530A fourier transform infrared spectroscopy

 

 

products profile

FTIR-530A fourier transform infrared spectroscopy 

case

FTIR-530A fourier transform infrared spectroscopy 

company profile

FTIR-530A fourier transform infrared spectroscopy 

exhibition

FTIR-530A fourier transform infrared spectroscopy 

packing

FTIR-530A fourier transform infrared spectroscopy 

FAQ

FTIR-530A fourier transform infrared spectroscopy 

payment methods

FTIR-530A fourier transform infrared spectroscopy 

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Hi~