AAS 200 Graphite Furnace Flame Atomic Absorption Spectrophotometer Price
USD $24,150 - $24,900 /Piece
Min.Order:1 Piece
Shanghai Drawell Scientific Instrument Co., Ltd.
FEATURES:
Integrated flame/graphite furnace atomization system, changeable with flame emission burner
Accurate fully automated control system
Reliable fully automatic graphite furnace analysis
Perfect safety protection measures
· Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system;
· Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling water supply and over-heating in graphite furnace system.
· Adopting large-scale programmable logic array and Inter I2C bus technology
· European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system.
· Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and optimization.
· Automatic sample dilution, automatic curve fitting, automatic sensitivity correction.
· Automatic calculation of sample concentration (content), mean value, standard deviation and relative standard deviation calculation.
· Multi-elements determination in sequence to the same sample.
· Measured data and final results can be printed out and edited in Excel format.
SPECIFICATIONS:
Main Specification |
Wavelength range |
190-900nm |
Wavelength accuracy |
Better than ±0.25nm |
|
Resolution |
Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. |
|
Baseline stability |
0.004A/30min |
|
Background correction |
The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times. |
|
Light Source System |
Lamp turret |
Motorized 6-lamp turret (Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis.) |
Lamp current adjustment |
Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA. |
|
Lamp power supply mode |
400Hz square wave pulse; 100Hz narrow square wave pulse + 400Hz wide square pulse wave. |
|
Optical System |
Monochomator |
Single beam, Czerny-Turner design grating monochromator |
Grating |
1800 l/mm |
|
Focal length |
277mm |
|
Blazed Wavelength |
250nm |
|
Spectral Bandwidth |
0.1nm, 0.2nm, 0.4nm, 1.2nm, auto switch over |
|
Flame Atomizer |
Burner |
10cm single slot all-titanium burner |
Spray chamber |
Corrosion resistant all-plastic spray chamber. |
|
Nebulizer |
High efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7mL/min |
|
Emission burner provided |
||
Graphite Furnace |
Temperature range |
Room temperature~3000ºC |
Heating rate |
2000℃/s |
|
Graphite tube dimensions |
28mm (L) x 8mm (OD) |
|
Characteristic mass |
Cd≤0.8 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g |
|
Precision |
Cd≤3%, Cu≤3%, Mo≤4% |
|
Detection and Data Processing System |
Detector |
R928 photomultiplier with high sensitivity and wide spectral range. |
Software |
Under Windows operating system |
|
Analytical method |
Working curve auto-fitting; standard addition method; automatic sensitivity correction; automatic calculation of concentration and content. |
|
Repeat times |
1~99 times, automatic calculation of mean value, standard deviation and relative standard deviation. |
|
Multi-task Functions |
Sequential determination of multi-elements in the same sample. |
|
Condition reading |
With model function |
|
Result printing |
Measurement data and final analytical report printout, editing with Excel. |
|
Standard RS-232 serial port communication |
||
Graphite Furnace Autosampler |
Sample tray capacity |
55 sample vessels and 5 reagent vessels |
Vessel material |
Polypropylene |
|
Vessel volume |
3ml for sample vessel, 20ml for reagent vessel |
|
Minimum sampling volume |
1μl |
|
Repeatable sampling times |
1~99 times |
|
Sampling system |
Accurate dual pump system, with 100μl and 1ml injectors. |
|
Characteristic Concentration and Detection Limit |
Air-C2H2 flame
|
Cu: Characteristic concentration ≤ 0.025 mg/L, Detection limit≤0.006mg/L;
|
Function Expansion |
Hydride vapor generator can be connected for hydride analysis. |
|
Dimensions and Weight |
Main unit |
107X49x58cm, 140kg |
Graphite furnace |
42X42X46cm, 65kg |
|
Autosampler |
40X29X29cm, 15kg |