Product Introduction
ADL3000-E is a smart meter designed for power supply system, industrial and mining enterprises and utilities to calculate the electricity consumption and manage the electric demand. It features the high precision, small size and simple installation. It integrates the measurement of all electrical parameters with the comprehensive electricity metering and management provides various data on previous 12 months, checks the 31st harmonic content and the total harmonic content, realizes the remote communication and the remote control with switching input and relay output and boasts the alarm output. It is fitted with RS485 communication port and adapted to
MODBUS-RTU. DTSD1352 can be used in all kinds of control systems, SCADA systems and energy management systems. All meters meet the related technical requirements of electronic power meter in the IEC62053-21、IEC62053-22 standards.
Product Functions
Function | Function description | Function provide |
Measurement of kWh | Active kWh (positive and negative) | ■ |
Reactive kWh (positive and negative) | ■ | |
A, B, C phase positive active kWh | ■ | |
Measurement of electrical parameters |
U、IP、Q、S、PF、F | ■ |
■ | ||
Measurement of | 2~31st Voltage and current harmonic | □ Note 1 |
LCD Display | 8 bits section LCD display, background light | ■ |
Key programming | 4 keys to communication and set parameters | ■ |
Pulse output | Active pulse output | ■ |
Reactive pulse output | □ Note 2 | |
Clock pulse output | □ Note 2 | |
LED alarm | Alarm on voltage loss and overvoltage | ■ |
Multi-tariff and functions | Active switch input | □ Note 3 |
Switch output | □ Note 2 | |
Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates | □ | |
Max demanded kWh and time happened | □ | |
Frozen data on last 48 months, last 90days | □ | |
Date, time | □ | |
Communication | Infrared communication | ■ |
The first communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU | £ | |
The second communication path: Communication interface: RS485, Communication protocol: MODBUS-RTU |
□ Note 3 | |
Temperature measurement | Support 3 outlay NTC temperature | □ Note 4 |
Note:
1: Harmonic is a standard while choosing outlay transformer, optional for other situation. 2: Reactive pulse output, clock pulse output and switching output: Choose one of these
three.
3: Active switching, the second communication path: Choose one of these two. 4: Both 1 and 2 cannot be chosen while choosing temperature measurement.
Technical Parameters
Specification | 3 phase 3 wires, 3 phase 4 wires | |
Voltage | Reference voltage | 3×100V、 3×380V、3×57.7/100V、 3×220/380V |
Consumption | <10VA(Single phase) | |
Impedance | >2MΩ | |
Accuracy class | Error±0.2% | |
Current | Input current | 3×1(6)A,3×1(6)A(Outlay transformer),3× 10(80)A |
Consumption | <1VA(Single phase rated current) | |
Accuracy class | Error±0.2% | |
Power | Active, reactive, apparent power, error±0.5℅ | |
Frequency | 45~65Hz,Error±0.2% | |
Temperature | -40℃~99℃ | |
Energy | Active energy(Accuracy class:0.5, 1), reactive energy(Accuracy class 2) | |
Clock | ≤0.5s/d | |
Energy pulse output | 1 active optocoupler output, 1 reactive optocoupler outpu | |
Switching output | 1 Switching output | |
Switching input | 1 optocoupler input | |
Width of pulse | 80±20ms | |
Pulse constant | 6400imp/kWh,400imp/kWh(Correspond with the basic current) | |
Interface and communication | RS485:Modbus RTU | |
Range of communication address | Modbus RTU:1~ 247; | |
Baud rate | 1200bps~19200bps | |
Relative temperature | -25℃~+55℃ | |
Relative humidity | ≤95℅(No condensation) |
Dimension Drawing(Unit:mm)
connect via CT
derect connect
Certificate
Customers
Company Profile
Acrel Co.,Ltd.[Stock Code:300286.SZ] is a professional company in china who provides various systematic solutions of power monitoring,energy management and electrical safety for smart grid users.
Since June 2003,we have always been focused on the research,production and sales of intelligent electric meters.We concentrate on providing products and services to help customers improve electricity efficiency and safety.So far we have had the following comprehensive solutions for different applications:35(10)/0.4KV substation antomation system,power quality management system for medical location,precise distribution management system,smart lighting control system,remote orepayment metering system and motor control center.
Jiangsu Acrel Electrical Manufacturing Co.,LTD,our production base in Jiangyin City,Wuxi,provides guarantee for the industrialization and large-scare implementation of products.The annual production capacity of various meters is 2 million units,and more than 1.3 million units are sold in 2018.
Since the listing in 2012,our company has maintained steady growth.The company will adhere to the concept of“innovation,efficiency,unity,integrity”,adhere to steady operation and continuous innovation,and provide more high-quality products,services and silutions for power system users and micro-grid.
Contact