Acrel ADL3000-E three phase Din rail RS485 modbus electricity energy meter
Acrel ADL3000-E three phase Din rail RS485 modbus electricity energy meter
Acrel ADL3000-E three phase Din rail RS485 modbus electricity energy meter
Acrel ADL3000-E three phase Din rail RS485 modbus electricity energy meter
Acrel ADL3000-E three phase Din rail RS485 modbus electricity energy meter

Acrel ADL3000-E three phase Din rail RS485 modbus electricity energy meter

USD $70 - $70.1 /Piece

Min.Order:1 Piece

Supply Ability:
10000 Piece / Pieces per Month
Port:
Shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Other Cash Escrow
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Acrel
Place of Origin:
China
Model Number:
ADL3000-E
Phase:
Three Phase
Output Voltage:
220V
Operating Temperature:
-25℃~55℃

Jiangsu Acrel Electrical Manufacturing CO.,LTD

Business license
Business Type: Manufacturer
Wuxi Jiangsu China
Main Products: power sensor ,programmable power meter ,DC power analyzer ,Data center monitor device ,Din rail energy meter ,Isolated power supply ,wireless temperature sensor ,IOT energy meter ,split core current transformer

Product Details

Technical consulting: Tina Li

Tel/Whatsapp:+86 15161626103

Email:sales02@email.acrel.cn

Product Introduction

ADL3000-E is a smart meter designed for power supply system, industrial and mining enterprises and utilities to calculate the electricity consumption and manage the electric demand. It features the high precision, small size and simple installation. It integrates the measurement of all electrical parameters with the comprehensive electricity metering and management provides various data on previous 12 months, checks the 31st harmonic content and the total harmonic content, realizes the remote communication and the remote control with switching input and relay output and boasts the alarm output. It is fitted with RS485 communication port and adapted to

MODBUS-RTU. DTSD1352 can be used in all kinds of control systems, SCADA systems and energy management systems. All meters meet the related technical requirements of electronic power meter in the IEC62053-21IEC62053-22 standards.

Product Functions

Function

Function description

Function provide

Measurement of kWh

Active kWh (positive and negative)

Reactive kWh (positive and negative)

A, B, C phase positive active kWh

Measurement of electrical parameters

 

UIPQSPFF

Measurement of

2~31st Voltage and current harmonic

Note 1

LCD Display

8 bits section LCD display, background light

Key programming

4 keys to communication and set parameters

 

 

 

Pulse output

Active pulse output

Reactive pulse output

Note 2

Clock pulse output

Note 2

LED alarm

Alarm on voltage loss and overvoltage

 

 

 

 

 

 

 

Multi-tariff and functions

Active switch input

Note 3

Switch output

Note 2

Adapt 4 time zones, 2 time interval lists, 14

time interval by day and 4 tariff rates

Max demanded kWh and time happened

Frozen data on last 48 months, last 90days

Date, time

 

 

 

 

 

 

Communication

Infrared communication

The first communication path: Communication interface: RS485,

Communication protocol: MODBUS-RTU

£

The second communication path:

Communication interface: RS485, Communication protocol: MODBUS-RTU

 

 

Note 3

Temperature measurement

Support 3 outlay NTC temperature

Note 4

Note:

1: Harmonic is a standard while choosing outlay transformer, optional for other situation. 2: Reactive pulse output, clock pulse output and switching output: Choose one of these

three.

3: Active switching, the second communication path: Choose one of these two. 4: Both 1 and 2 cannot be chosen while choosing temperature measurement.

 

Technical Parameters

Specification

3 phase 3 wires, 3 phase 4 wires

 

 

 

Voltage

Reference voltage

3×100V3×380V3×57.7/100V3×220/380V

Consumption

<10VA(Single phase)

Impedance

>2MΩ

Accuracy class

Error±0.2%

 

Current

Input current

3×1(6)A3×1(6)A(Outlay transformer)3× 10(80)A

Consumption

<1VA(Single phase rated current)

Accuracy class

Error±0.2%

Power

Active, reactive, apparent power, error±0.5℅

Frequency

4565HzError±0.2%

Temperature

-40℃~99

Energy

Active energy(Accuracy class:0.5, 1), reactive energy(Accuracy

class 2)

Clock

0.5s/d

Energy pulse output

1 active optocoupler output, 1 reactive optocoupler outpu

Switching output

1 Switching output

Switching input

1 optocoupler input

Width of pulse

80±20ms

Pulse constant

6400imp/kWh,400imp/kWh(Correspond

with the basic current)

Interface and communication

RS485Modbus RTU

Range of communication

address

Modbus RTU:1~ 247

Baud rate

1200bps~19200bps

Relative temperature

-25~+55

Relative humidity

≤95℅(No condensation)

 

Dimension Drawing(Unit:mm)

connect via CT

 

derect connect


Certificate

 

Customers

 

Company Profile

Acrel Co.,Ltd.[Stock Code:300286.SZ] is a professional company in china who provides various systematic solutions of power monitoring,energy management and electrical safety for smart grid users.

Since June 2003,we have always been focused on the research,production and sales of intelligent electric meters.We concentrate on providing products and services to help customers improve electricity efficiency and safety.So far we have had the following comprehensive solutions for different applications:35(10)/0.4KV substation antomation system,power quality management system for medical location,precise distribution management system,smart lighting control system,remote orepayment metering system and motor control center.

Jiangsu Acrel Electrical Manufacturing Co.,LTD,our production base in Jiangyin City,Wuxi,provides guarantee for the industrialization and large-scare implementation of products.The annual production capacity of various meters is 2 million units,and more than 1.3 million units are sold in 2018.

Since the listing in 2012,our company has maintained steady growth.The company will adhere to the concept ofinnovation,efficiency,unity,integrity”,adhere to steady operation and continuous innovation,and provide more high-quality products,services and silutions for power system users and micro-grid.

 

Contact

Contact Supplier

Mr. Tim Overseas sales engin Chat Now
Telephone
86-1870-6168051
Mobile
86-18761599716
Fax
86-1870-86179975
Skype
86 18761599716
Address
Jiangyin Wuxi,Jiangsu
Whatsapp
86 18761599716

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Energy Meters
Categories
Hi~