worm gear operator for electric actuator 2sa5021+gs160-gz14(8:1) 2sa5021+gs200-gz16(16:1)
worm gear operator for electric actuator 2sa5021+gs160-gz14(8:1) 2sa5021+gs200-gz16(16:1)
worm gear operator for electric actuator 2sa5021+gs160-gz14(8:1) 2sa5021+gs200-gz16(16:1)
worm gear operator for electric actuator 2sa5021+gs160-gz14(8:1) 2sa5021+gs200-gz16(16:1)
worm gear operator for electric actuator 2sa5021+gs160-gz14(8:1) 2sa5021+gs200-gz16(16:1)

worm gear operator for electric actuator 2sa5021+gs160-gz14(8:1) 2sa5021+gs200-gz16(16:1)

USD $600 - $1300 /Piece

Min.Order:1 Piece

Supply Ability:
100 Piece / Pieces per Month
Port:
TIANJIN XINGNAG PORT
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Other Cash Escrow
Delivery Detail:
15 days

Quick Details View All >

Brand Name:
Freya
Place of Origin:
China
Model Number:
2sa5021+gs160-gz14(8:1) 2sa5021+gs200-gz16(16:1)

TIANJIN FREYA AUTOMATION TECHNOLOGY CO., LTD

Business license
Business Type: Manufacturer
Tianjin China
Main Products: electric actuator ,bernard actuator ,electric valve ,electrical damper

Product Details

 _01.jpgxibosi_03.jpg


_03.jpg

 12.jpg

 _08.jpg

 

 13.jpg

 

parameter setting

 

14.jpg

         Quarter-turn actuator adjustable ratio of the signal gear unit

                                             16.jpg

28.jpg

 _11.jpg

            29.jpg

 
1. Local operation
Local operation includes the following contents: see picture 4-1 Operation Faceplate Diagram
Terminal(standard )
standard(Metric)
 information center
operation button
LED light
1 information center
LCD screen provides the actuator’s information of operation mode, position, parameter setting choices, parameter input, information feedback and alarm information.
2 operation buttons
You can choose the control operation sites of actuator (local/remote) via the operation buttons, and running the actuator locally at the same time. There are four buttons provide different functions (see table 4-1).
3 LED Light
LED blue light blinking indicates the actuator is opening or closing, red light indicates the actuator fails to work properly.
2. remote operation
Remote operating command depends on the parameter switching value and setting of switching value mode, through:
Operate by switching input terminals (on, off, stop and emergency) and analog input channels.
Operate by Profibus DP or modbus RTU manual operate.
Warning: hand shrank (hand wheel) can be connected to the interior worm when the actuator is not operating.
Warning: After debugging, the operating of actuator with hand shrank should be confined to the scope of terminal position set before. Otherwise, the scope has to be reset.
Clockwise rotation of the hand shrank (hand wheel) will lead to:
Clockwise rotation (seen from the side of worm-gear box marked with arrow) of Quarter-Turn actuator when the worm-gear box is RR.
1.Press the handle/handwheel in the direction towards gearbox and overcome the resistance of the spring, then users can switch the motor operation mode to manual opeartion mode.
2. Manual operation is preferential compared to motor operation. Motor operation is possible only when hand shrank is loose.
_14.jpg
Installing the Electric Actuator to the Valve
1 Notice: the flange plate of valve and electric actuator should be cleaned thoroughly with greasy dirtying,
wiped off surface oil.
2 Small amount of oil should be applied to the connection part.
3 The electric actuator should be accurately installed to the valve.
4 Bolts should be at least 8.8 in respect of level of performance (spring shims should be used to fixed bolts).
5 Torque of swivel bolt is M8 (23Nm) ; MlO (68Nm) ; M16 (305Nm) ; M20 (500Nm).

 18.jpg

 

Type A output shaft should be first processed. If not, please process according to the following steps:
(1) Locating ring D should be unscrewed from flange plate.
(2)Thread bushing A, needle bearing C and bearing shim B should be taken down together.
(3)Needle bearing C and bearing shim B should be taken down from thread busing A. Then the thread should.
be taped out (check concentricity and beating rate after installation) and cleaned.
(4)Ball bearing greasy should be applied to needle bearing C and bearing shim B and attach them to thread bushing A.
(5)Thread bushing A and the bearing should be inserted into the flange of output shaft.
(6)Screw locating ring D in until it is fixed.
(7)Ball bearing greasy should be applied through zerk with greasy gun until oil runs out of the centering ring.
(8)Then hand shank or hand heel should be used to rotated electric actuator so the thread will move to the drive bolts of the valve.
(9)Finally, the flange mounting surface of electric actuator and that of valve should be fastened by bolt when they are next to each other.
Important : please screw the fixing screw nut to make sure the valve-stem drive nut won’t fall off.

_19.jpg 

 

Shipment Term:

1. Orders processed timely after the payment verification .

2. Terms of Deliver: FOB / CFR / CIF / EXW etc.

3. Due to stock status and time differences , we will choose to ship your item from our first available warehouse for fast delivery .

Payment Term:

1. Accept T/T, D/A, D/P, L/C, West Union with 30% Deposit.

2. Advance payment should be made within 3 days of order .

Our Services

Our company provides you with the following services free of charge:

1. All-round electric actuator and valve technology selection service

2. High-quality post-product maintenance and technical analysis services

3. Accept other related cooperation.

 


Contact Supplier

Ms. Alice Sales Manager Chat Now
Mobile
86-18322091940
Skype
freyatianjin01
Address
ROOM C,8TH FlOOR,TIANJIN ENERGY SAVING BUILDING,NO.80 XINGGUANG ROAD,ZHONGBEI TOWN,XIQING DISTRICT,TIANJIN,CHINA Tianjin

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Other Electrical Equipment
Categories
Hi~