Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting
Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting
Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting
Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting
Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting
Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting
Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting

Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting

USD $1.05 - $1.05 /Meter

Min.Order:100 Meters

Supply Ability:
50000 Piece / Pieces per Month
Port:
Any port in China
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Youyu
Place of Origin:
Anhui, China
Model Number:
OEM

Anhui Youyu Electric Heating Equipment Co., Ltd.

Business license
Business Type: Manufacturer
Wuhu Anhui China
Main Products: Drainline Heating Cable ,MI Armored Heating Cable ,Single & Twin Conductor Heating Cable ,Constant Wattage Heating Cable

Product Details

Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting

Product Description

Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting

Product Dispaly of 2018 Best Price Custom Watery Resistant 18w Single Core Heating Cable

 

Single conductor heating cable
Twin conductor heating cable
1.Nickel alloy wire1.Nickel alloy wire
2.8 tinned copper wire2.8 tinned copper wire
3.Cross-linked PE insulation3.Cross-linked PE insulation
4.Armored shield4.Armored shield

5.PVC jacket

5.PVC jacket

 

Product Application

Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting

The single-conductor industrial heating system assembly use an implicit connector, the core of the industrial heating system is composed of a hot-cold wire, and the outside is made up of an insulating layer, a earth wire, a shielding layer and a sheath layer.After the industrial heating system is energized, the heating wire generates heat, running between the temperature 40-60 ℃, buried in the filler layer of industrial heating system, through the way of heat conduction and far-infrared radiation to the heated body.Twin conductor industrial heating system with implicit connector, industrial heating system core by the cold and hot cable, the outside by the insulation layer, earth wire, shielding and outer sheath composition. After the industrial heating system is energized, the heating wire generates heat and runs at a temperature between 40 and 60 degrees. The industrial heating system embedded in the filling layer will be transmitted to the heating body through heat conduction and far-infrared radiation. Twin conductor industrial heating system is mainly used for floor heating, soil heating, snow melting , livestock breeding.

Installation Steps

Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting

 

Company Information

Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting 

Client & Certificate

Manufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow MeltingManufacturer Ex-Factory PriceElectric Snow Melting Heating Cable Use In Roof De-icing And Snow Melting 

FAQ

1. How much electricity is consumed per hour?

Consider an average room size of 100m2 . The heated area is approximately 80%, or 80m2 .

In the case of the 150W mats, when the heater is ON, the hourly consumption is 1500W times 80m2.

When the recommended thermostat is turned on, take 100m2 as an example. The room is filled with heat about 20min~30min, which is between 450W and 750W. Of course, the specific cost depends on your electricity consumption and electricity unit price.

 

2. Do I use insulation materials?

We recommend that you use insulation materials. On the one hand, it is for your safety considerations, on the other hand, because it can lock the heat, the preheating will be faster, and the power consumption will be reduced.

 

3. Is it safe to use in a humid place?

Yes, our products are of high quality and have a grounding wire.

 

4.  How long is the warranty time?

25 years for heating cable & heating mat.

2 years for for constant wattage/self-regulating heating cable and thermostats.

 

5. Can I crop it?

Yes, you can crop the grid

 

6. What is the thickness of the cable?

The cable is 3.5mm thick.

Contact Supplier

Ms. Joanna Lu Sales Executive Chat Now
Telephone
86-553-2667735
Mobile
86-14755302790
Skype
86 14755302790
Address
High-tech Industrial Development Zone Wuhu,Anhui
Whatsapp
86 14755302790

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Hi~