Acrel ARD2-5 timeout startup, over load ,phase failure, unbalance, blocking, short circuit 0.12KW 0.37KW 0.55KW  motor protector
Acrel ARD2-5 timeout startup, over load ,phase failure, unbalance, blocking, short circuit 0.12KW 0.37KW 0.55KW  motor protector
Acrel ARD2-5 timeout startup, over load ,phase failure, unbalance, blocking, short circuit 0.12KW 0.37KW 0.55KW  motor protector

Acrel ARD2-5 timeout startup, over load ,phase failure, unbalance, blocking, short circuit 0.12KW 0.37KW 0.55KW motor protector

USD $84 - $84 /Set

Min.Order:1 Set

Supply Ability:
1000 Set / Sets per Month
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Acrel
Place of Origin:
Jiangsu, China
Model Number:
ARD2

Jiangsu Acrel Electrical Manufacturing CO.,LTD

Business license
Business Type: Manufacturer
Wuxi Jiangsu China
Main Products: power sensor ,programmable power meter ,DC power analyzer ,Data center monitor device ,Din rail energy meter ,Isolated power supply ,wireless temperature sensor ,IOT energy meter ,split core current transformer

Product Details

Product Description

1,Overview

ARD series intelligent motor protector (hereinafter referred to as protector) can perform various conditions such as start timeout, overload, phase failure, unbalance, underload, ground/leakage, blockage, short circuit and external fault during motor operation. Protection, and SOE fault event recording function, convenient for on-site maintenance personnel to find the cause of the fault. Suitable for coal, petrochemical, smelting, electric power, ships, and civil construction. The protector has RS485 remote communication interface, DC 4 ~ 20mA analog output, and PLC, PC and other control machines form a network system. Remote monitoring of motor operation.

 

2,Model Description

l ARD2(L) intelligent motor protector

 

Table 4 Design serial number

Design serial number

Specification

Design serial number

Specification

2

Digital tube display

2L

LCD

Table5 Rated current

Protector rated current(A)

Ratio setting

Transformer primary side turns

Setting current Is range(A)

Motor Power(kW)

1

Need to set

5

0.1~999.9

0.12~440

5

1

0.1~999.9

0.12~440

1.6

No need to set

1

0.4~1.6

0.12~0.55

6.3

1

1.6~6.3

0.75~2.2

25

1

6.3~25

3~11

100

1

25~100

15~45

250

1

63~250

55~132

800

1

250~800

160~440

Table 6 Additional features

Additional features

Code

Additional features

Code

Communication Interface

C

2 switch input; 1 relay output (programmable 3)

K

Leakage Protection

L

SOE record

SR

4~20mA analog output

M

Alarm output (programmable 2)

J

Note: 1. When the additional function is equipped with leakage protection L, it is necessary to purchase zero-sequence transformers with different apertures according to the actual current.

 

 

Packaging & Shipping

Acrel ARD2-5 timeout startup, over load ,phase failure, unbalance, blocking, short circuit 0.12KW 0.37KW 0.55KW  motor protector

Our Services

 Acrel ARD2-5 timeout startup, over load ,phase failure, unbalance, blocking, short circuit 0.12KW 0.37KW 0.55KW  motor protector

 

Company Information

 Acrel ARD2-5 timeout startup, over load ,phase failure, unbalance, blocking, short circuit 0.12KW 0.37KW 0.55KW  motor protector

 

FAQ

Cautions
1.For the primary circuit, three-phase current threading direction shall keep consistent, or else, the ground protection will be in error.

2.When the protector is equipped with ground/leakage protection function, the protector wire from the leakage transformer shall be shielded conductor, or else, the measured data may be incorrect.

3.The rated current (P055) of the protector shall be set rationally. If the set value is less than the normal rated working current, the motor may not start normally; if the set value is more than the normal rated working current, the protector cannot provide the normal protection in case of motor fault.

4.If the protector trips, after the fault is eliminated and before the motor is started, please reset the protector, or else, the motor cannot be started.

5.Motor cooling time: 30min.After the motor overload protection actuated (fault displayed as hEAt), after cooling, it can rest due to heat accumulation.

6.In the actual use on the site, as the protector parameter setting is not rational, the motors may be protected together or are not protected. At this moment, all protection functions will be off. All protection parameters of the protector are set again according to all parameters measured during motor normal operation.

7.If all protection parameters of the protector are appropriate, once the motors actuate together, the protector will work. At this moment, the fault cause is searched according to the actuation code of protector.

8.The protector parameters are defaulted during delivery (except the user’s special requirements). The user may enable all protection functions according to the actual need and set all parameters.

9.If the primary current is 1000A, the external transformer is 1000A/5A. When the protector is connected again, the protector with 5A of current is selected and CT transformation ratio is 200.

Contact Supplier

Mr. Tim Overseas sales engin Chat Now
Telephone
86-1870-6168051
Mobile
86-18761599716
Fax
86-1870-86179975
Skype
86 18761599716
Address
Jiangyin Wuxi,Jiangsu
Whatsapp
86 18761599716

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Hi~