Wet leakage testing equipment/Wet leakage current testing machine/Solar panel testing machine with IEC61215 testing
Standard
It's conform IEC61215-2:2016 & IEC61730-2:2016 testing standard
Purpose
to evaluate the insulation of the module under wet operating conditions and verify that moisture from rain, fog, dew or melted snow does not enter the active parts of the module circuitry , where it might cause corrosion, a ground fault or a safety hazard
The Main Technical Specificatios
Test tank | size:2500×1500×250mm(W*D*H),thickness 15mm, material:plexiglass |
Temperature control | water constant temperature system researched and development by HOTOTECH , temperature:22±3℃ |
Liquid resistivity | less than 3500Ω·cm |
Programmable insulation withstand voltage tester | 1.Output current the maximum 0-5000V (adjustable) 2.Leakage current the maximum limit value:5mA 3.Output speed rate:500V/S 4.Insulation resistance test range:1MΩ~9999MΩ 5.Leakage current test range:0.001~5.000mA(DC) |
Main configuration | 1.Insulation withstand voltage tester 2.Water constant temperature system (control box) 3.Insulation water tank 4.Conductivity meter |
Electricity | 220V 50HZ |
Customer Site demand
NO | Project | Requirement |
1 | Placed dimension | 2390×1330×2420mm(L×W×*H) |
2 | Weight | Approx 220kg |
4 | Power supply | 1 Phase 220V 50HZ |
5 | Gound | Ground line connect to the ground |
6 | Area requirment | Fat |
Testing Procedure
1.All connections shall be representative of the recommended field wiring installation , and precautions shall be taken to ensure that leakage currents do not originate from the instrumentation wiring attached to the module
2.Immerse the module in the tank of the required solution to a depth sufficient to cover all surfaces except
junction box entries not designed for immersion. If not immersed the cable entries shall be thoroughly sprayed with solution, if the module is provided with a mating connector, the connect should be sprayed during the test.
3.Connect the shorted output terminals of the module to the positive terminal of the test equipment , connect
the liquid test solution to the negative terminal of the test equipment using a suitable metallic conductor
4.Connect the shorted output terminals of the module to the positive terminal of the test equipment, connect the liquid test solution to the negative terminal of the test equipment using a suitable metallic conductor
5.Some module technologies may be sensitive to static polarization if the module is maintained at positive voltage to the frame, in this case , the connection of the tester shall be done in the opposite way, if applicable, information with respect to sensitivity to static polarization shall be provided by manufacturer
6.Increase the voltage applied by the test equipment at a rate not exceeding 500V/s to 500V or the maximum system voltage for the module , whichever is greater. Maintain the voltage at this level for 2min, then determine the insulation resistance
7.Reduce the applied voltage to zero and short-circuit the terminals of the test equipment to discharge the voltage build-up on the module
8.Ensure that the used solution is well rinsed off the module before continuing the testing
You May Like
- Salt spray tester/Salt Mist Aging Testing Chamber / Solar panel testing chamber for IEC61730 testing
- Photovoltaic module breach testing machine/Glass impact Testing equipment/Solar panel testing machine for IEC 61730
- Damp Heat Testing Machine/constant temperature and humidity testing chamber/Solar panel evnironment chamber with IEC61215
- Solar panel ice ball impact testing machine/Solar panel testing equipment/Hail impact tester with IEC61215-2:2016 standard
- IEC61215 standard Solar panel UV preconditioning testing Machine/UV preconditioning test chamber/solar panel testing equipment
- PV module Terminal Box knockout tester/PV Module testing machine/Solar panel testing equipment for IEC61730 standard
- Terminal Box Knockout tester/Junction box Orifice cover strike off testing machine/PV Module testing equipment with IEC61730
- Solar panel Guide wire tube bending testing machine/Conduit Bending Testing Machine/PV Module testing equipment with IEC61730
- PV Module Hail impact testing /Hail Impact Tester with IEC61215-2:2016 standard
- Programmable constant temperature and humidity test chamber /testing machine /testing equipment for solar panel
Popular Searches
Find Similar Products By Category
You May Like
- Solar panel Mechanical Load Universal testing machine/Pressure testing machine for IEC61215-2:2016 standard
- Dynamic Mechanic Loading Tester/Solar panel testing equipment / PV Module testing machine with IEC61215 & IEC61730 testing
- Mechanical load test system/ Mechanical Load Tester / PV Module testing equipment with IEC61215-2:2016 testing standard
- IEC61215-2:2016 the newest standard PV Module Cord Anchorage pull testing equipment/ Solar panel testing
- Solar Panel Test PV Module of Mechanical Load Tester
- Hot selling Wet leakage testing equipment/Wet leakage current testing machine/Solar panel testing machine
- Solar Panel salt spray tester/Salt Mist Aging Testing machine / Solar panel testing machine for IEC61730 testing
- Photovoltaic module breach testing machine/Solar module Testing equipment/Solar panel testing apparatus for IEC 61730 stndard
- PV Module Damp Heat Testing Machine/constant temperature and humidity testing chamber/evnironment chamber
- PV module Damp Heat Tester/Solar panel damp heat testing machine / constant temperature and humidty environment chamber
- Solar panel ice ball impact testing machine/Clash testing machine/Solar panel testing machine with IEC61215-2:2016 standard
- Salt Spray Testing Machine /PV Module testing chamber/Salt mist testing machine for pv module with IEC61701 testing
- photovoltaic conduit bend testing machine/guide tube winding testing equipment /testing apparatus with IEC standard
- IEC61215 standard Solar panel UV preconditioning testing Machine/UV preconditioning test chamber/solar panel testing machine
- Conduit Bending Testing Machine/Solar panel testing machine/PV Module Testing Machine with IEC61730