Photovoltaic module breach testing machine/Glass impact Testing equipment/Solar panel testing machine for IEC 61730
USD $5,688.62 - $6,287.42 /Set
Min.Order:1 Set
Photovoltaic module breach testing machine/Glass impact Testing equipment/Solar panel testing machine for IEC 61730
Testing standard
It's conform IEC61730-2:2016 testing standard
Purpose
The purpose of this test is to provide confidence that risk of physical injuries can be minimized if the module is broken in its specified installation
The Main Technical Specifications
Frame the Struction frame raw materials | Steel channel ( approx the width ≥100mm ) |
Fixture ways | use the bolted to the floor to prevent movement during impact testing |
The inner dimension of test frame | 2.2×1.3m (It’s adjustable, suit for diffferent dimension of pv modules testing) |
The sample frame with the rubber bar and the thickness | 3mm, wide 15mm, hardness shore A50° |
The exterior of the bag | according to the standard use the wrapped with tape |
The inner filling diameter | 2.5-3.0mm ( the material is pellets or steel ball ) |
The mass of impactor | 45.5 ± 0.5kg |
The ratio of widest diameter to height is between | 1:1,5 to 1:1,4 |
Safety Function | With the safety protection frame and Anti-secondary impact function |
Impact height | 300mm , 450mm, 600mm, 750mm, 900mm, 1200mm |
Impact height display accurate | 0.1mm |
Impactor rise ways | Automaitc rise/ Jog rise |
Release ways | arriving predetermined height, the cylinder automatic release |
Display data | Real-time display rise height |
Control ways | Touch screen control |
Electricity | 220V 50HZ |
Testing procedure
1. At rest the impactor bag shall hang no more than 13mm from the surface of the pv module sample and no more than 50mm from the centre of the pv module sample
2.Lift the impactor to a drop height of 300mm from the surface of the pv module sample, allow the impactor to stabilize and then release it to impact the pv module sample
Customer site requirement
NO | Item | Requirement |
1 | Placed dimension | 2730×2000×3350mm +control box 350×350×1020mm |
2 | Weight | Approx 1.5 ton |
3 | Compressor air requirement | ≥0.6Mpa |
4 | Power requirement | 1 phase 220V 50HZ |
5 | Gruond requirement | Ground line connect to the ground |
6 | Area requirement | Flat |
7 | Envirnoment requirement | 20℃±2%,humidity 50%~70%, no noise , Shockproof, non-magnetic interference |
8 | Power | 1800W |