Grounding Resistance Tester earth resistance measurement soil resistivity meter
USD $466.67 - $466.67 /Unit
Min.Order:1 Unit
Digital Megohmmeter megge r5000v digital insulation resistance tester
Soil Resistivity Grounding Resistance Tester Grounding Voltage AC Voltage Measurement
60kV high-voltage primary currents Wireless high and low voltage current ratio tester
True RMS Digital AC Clamp Meter Pocket Size clamp on earth tester
HT3001 Soil resistivity grounding resistance tester
I. Product Introduction
HT3001 soil resistivity grounding resistance tester, also called the soil resistivity tester, is a commonly used instrument for measuring commonly used grounding resistance meters.
II. Technical Specification
1.Range and Accuracy error
Measurement function | Measurement range | Accuracy | Resolution |
Grounding resistance (R) | 0.00Ω~30.00Ω | ±2%rdg±5dgt (remark 1) | 0.01Ω |
30.0Ω~300.0Ω | ±2%rdg±3dgt | 0.1Ω | |
300Ω~3000Ω | ±2%rdg±3dgt | 1Ω | |
3.00kΩ~30.00kΩ | ±2%rdg±3dgt | 10Ω | |
Soil resistivity (ρ)
| 0.00Ωm~99.99Ωm | ρ=2πaR (remark 2) | 0.01Ωm |
100.0Ωm~999.9Ωm | 0.1Ωm | ||
1000Ωm~9999Ωm | 1Ωm | ||
10.00kΩm~99.99kΩm | 10Ωm | ||
100.0kΩm~999.9kΩm | 100Ωm | ||
1000kΩm~9999kΩm | 1kΩm | ||
Grounding voltage | AC 0.00~100.0V | ±2%rdg±3dgt | 0.01V |
Remark:
1. Reference conditions: accuracy with Rh Rs < 100Ω.
Working conditions:Rh max=3kΩ+100R<50kΩ;Rs max=3kΩ+100R<50kΩ
2.Depends on the measurement accuracy of R,π=3.14, a:1 m~100m
2.General specification
Two three four-wire measure grounding resistance, soil resistivity; Ground voltage, AC voltage measurement | |
Range | Grounding resistance: 0.00Ω~30.00kΩ |
Soil resistivity: 0.00Ωm~9999kΩm | |
Grounding voltage: 0.00V~100.0V | |
measurement mode | Precise four-wire, three-wire measurement, simple two-wire measurement |
Measurement methods | Grounding resistance: rated current change pole method Soil resistivity: four-pole method Ground Voltage: Average Rectification(between S-ES interface) |
Test frequency | 128Hz |
Short circuit test current | > 20mA (Sine Wave) |
Open circuit test voltage | AC 28V max |
Electrode spacing range | Can be set 1m ~ 100m |
Change gear | fully automatic shifting 0.00Ω ~ 30.00kΩ |
fully automatic shifting 0.00 Ωm~9000kΩm | |
Backlight | Controllable gray screen backlight, suitable for use in dim places |
Display mode | 4-bit large LCD display, gray screen backlight |
Measurement instructions | LED flashing indicator during measurement |
LCD size | 111mm×68mm |
LCD display field | 108mm×65mm |
Instrument size | L/W/H:277.2mm×227.5mm×153mm |
Standard test line length | 4 strips:red 15m,black 15m, yellow 10m,green 10m each one |
Simple test line | 2strips:yellow 1.6m,green 1.6m each one |
Auxiliary Grounding rod | 4PCS:φ10mm×200mm |
Power consumption | Standby: 40mA Max(Backlight off) |
Turn on backlight: about 43mA | |
measuring:75mA Max(Backlight off) | |
Weight | Instrument: 2450(including battery) |
Test lines:1300g | |
Auxiliary grounding rod: 850g(4PCS) | |
Working temperature and humidity | -10℃~40℃;below 80%rh |
Storage temperature and humidity | -20℃~60℃;below 70%rh |
Overload protection | Grounding resistance:AC 280V/3 seconds between H-E and S-ES ports |
Insulation resistance | More than20MΩ(500V between circuit and housing) |
Pressure resistance | AC 3700V/rms(between circuit and housing) |
Electromagnetic properties | IEC61326(EMC) |
Suitable for safety regulations | IEC61010-1(CAT Ⅲ 300V,CAT IV 150V,pollution level 2); IEC61010-031; IEC61557-1(grounding resistance); IEC61557-5(soil resistivity); JJG 366-2004. |
III. Accessories
Instrument | 1PC |
Instrument Box | 1PC |
Auxiliary grounding rod | 4PCS |
Standard test line | 4 Strips(red 15m;yellow 10m;green 10m;black 15m, each one) |
Simple test line | 2 Strips(yellow 1.6m;green 1.6m) |
6VLead-acid battery (internal) | 1PC |
Charger | 1PC |
Monitoring software CD | 1PC |
USB communication line | 1PC |
Manual, certificate | 1SET |