Soil Resistivity Grounding Resistance Tester Grounding Voltage AC Voltage Measurement
USD $456.36 - $466.67 /Set
Min.Order:1 Set
Soil Resistivity Grounding Resistance Tester Grounding Voltage AC Voltage Measurement
1.Range and Accuracy error
Measurement function | Measurement range | Accuracy | Resolution |
Grounding resistance (R) | 0.00Ω~30.00Ω | ±2%rdg±5dgt (remark 1) | 0.01Ω |
30.0Ω~300.0Ω | ±2%rdg±3dgt | 0.1Ω | |
300Ω~3000Ω | ±2%rdg±3dgt | 1Ω | |
3.00kΩ~30.00kΩ | ±2%rdg±3dgt | 10Ω | |
Soil resistivity (ρ) | 0.00Ωm~99.99Ωm | ρ=2πaR (remark 2) | 0.01Ωm |
100.0Ωm~999.9Ωm | 0.1Ωm | ||
1000Ωm~9999Ωm | 1Ωm | ||
10.00kΩm~99.99kΩm | 10Ωm | ||
100.0kΩm~999.9kΩm | 100Ωm | ||
1000kΩm~9999kΩm | 1kΩm | ||
Grounding voltage | AC 0.00~100.0V | ±2%rdg±3dgt | 0.01V |
Remark:
1. Reference conditions: accuracy with Rh Rs < 100Ω.
Working conditions:Rh max=3kΩ+100R<50kΩ;Rs max=3kΩ+100R<50kΩ
2.Depends on the measurement accuracy of R,π=3.14, a:1 m~100m
3001 soil resistivity grounding resistance tester, also called the soil resistivity tester, is a commonly used instrument for measuring commonly used grounding resistance meters. It uses a large LCD gray screen backlight display and microprocessor technology, through the microprocessor-controlled 2-wire, 3-wire, 4-wire method to test ground resistance and soil resistivity. It has a lot of grounding test function, can quickly and comprehensively measure the parameters in the grounding network.Widely used in telecommunications, electricity, meteorology, computer rooms, oil fields, power distribution lines, iron tower transmission lines, gas stations, factory grounding networks, lightning rods and so on. The instrument has the characteristics of precise, fast, simple, stable and reliable.
2.General specification
Function | Two three four-wire measure grounding resistance, soil resistivity; Ground voltage, AC voltage measurement |
Ambient temperature and humidity | 23℃±5℃,below 75%rh |
Power | DC 6V 4.5Ah lead-acid battery lasts more than 100 hours standby |
Interference voltage | <20V (should be avoided) |
Interference current | <2A (should be avoided) |
Measure R electrode spacing | a>5d |
Measured electrode spacing | a>20h |
Auxiliary ground resistance | Reference condition <100Ω, working condition <5kΩ |
Range | Grounding resistance: 0.00Ω~30.00kΩ |
Soil resistivity: 0.00Ωm~9999kΩm | |
Grounding voltage: 0.00V~100.0V | |
measurement mode | Precise four-wire, three-wire measurement, simple two-wire measurement |
Measurement methods | Grounding resistance: rated current change pole method Soil resistivity: four-pole method Ground Voltage: Average Rectification(between S-ES interface) |
Test frequency | 128Hz |
Short circuit test current | > 20mA (Sine Wave) |
Open circuit test voltage | AC 28V max |
Electrode spacing range | Can be set 1m ~ 100m |
Change gear | fully automatic shifting 0.00Ω ~ 30.00kΩ |
fully automatic shifting 0.00 Ωm~9000kΩm | |
Backlight | Controllable gray screen backlight, suitable for use in dim places |
Display mode | 4-bit large LCD display, gray screen backlight |
Measurement instructions | LED flashing indicator during measurement |
LCD size | 111mm×68mm |
LCD display field | 108mm×65mm |
Instrument size | L/W/H:277.2mm×227.5mm×153mm |
Standard test line length | 4 strips:red 15m,black 15m, yellow 10m,green 10m each one |
Simple test line | 2strips:yellow 1.6m,green 1.6m each one |
Auxiliary Grounding rod | 4PCS:φ10mm×200mm |
Measure time | Ground voltage:about 3 times/sec; |
grounding resistance,soil resistivity: about 7 seconds/time | |
Line voltage | Measurement below AC100V (ground voltage measurement function cannot be used to measure commercial power) |
USB interface | With USB interface, software monitoring, storage data can be uploaded to the computer, save and print |
Communication Line | One USB communication line, 1.5m long |
Data storage | 500 groups, "MEM" storage indicates, flashing "FULL" symbol indicates that the memory is full |
Data review | Data review function: "MR" symbol display |
Overflow display | Over-range overflow function: "OL" symbol display |
Interference test | Automatic identification of interference signals, "NOISE" symbol indication when the interference voltage is higher than 5V |
Auxiliary grounding test | With auxiliary ground resistance test function, 0.00KΩ ~ 30kΩ (Rh max = 3kΩ +100R <50kΩ; Rs max = 3kΩ +100R <50kΩ) |
Alarm function | Alarm when the measured value exceeds the alarm setting value |
Battery voltage | Real-time display of battery power, reminding timely charging when battery voltage is low |
Automatic Shutdown | “APO” Indicates, automatic Shutdown After 15 Minutes |
Power consumption | Standby: 40mA Max(Backlight off) |
Turn on backlight: about 43mA | |
measuring:75mA Max(Backlight off) | |
Weight | Instrument: 2450(including battery) |
Test lines:1300g | |
Auxiliary grounding rod: 850g(4PCS) | |
Working temperature and humidity | -10℃~40℃;below 80%rh |
Storage temperature and humidity | -20℃~60℃;below 70%rh |
Overload protection | Grounding resistance:AC 280V/3 seconds between H-E and S-ES ports |
Insulation resistance | 20MΩ(500V between circuit and housing) |
Pressure resistance | AC 3700V/rms(between circuit and housing) |
Electromagnetic properties | IEC61326(EMC) |
Suitable for safety regulations | IEC61010-1(CAT Ⅲ 300V,CAT IV 150V,pollution level 2); IEC61010-031; IEC61557-1(grounding resistance); IEC61557-5(soil resistivity); JJG 366-2004. |
Answer: Yes, we usually hold some quantities in stock, such as 100pcs or 200pcs are ready to ship immediately.
Answer: Normally it takes 3-5 working days after receiving payment.
Answer: We send by sea or by air including DHL/FedEx/TNT/UPS etc.
Answer: Yes, of course. OEM is absolutely supported; both on package or devices.
Answer: T/T,Paypal ,western union and trade assurance is welcome to us.