700w 3000RPM 24V Long lifetime small size brushless dc motor
USD $200 - $500 /Unit
Min.Order:1 Unit
HFM043 220v 4500w 4.5kw 5.5kw 3000rpm vibration neodymium magnet brushless dc electric motor for car
IEC frame 110V 3000RPM 0.7KW brushless dc motor for Automation
noiseless 3000rpm 800w 24v brushless dc motor for home application
Custom design 800w 3000rpm 12v 24v 48v 60v brushless dc motor
Smooth operation 3.18Nm 24V 1KW brushless dc motor with high efficiency
Motor type | Output | Voltage | Load | Speed | Rated Torque | Efficiency |
KW | V | A | RPM | N.m | % | |
VOL-BL075B48 | 0.75 | 48 | 16.98 | 3000 | 2.39 | 92 |
VOL-BL1K0C48 | 1 | 48 | 24.5 | 2500 | 3.82 | 85 |
VOL-BL1K2C24 | 1.2 | 24 | 63.3 | 4200 | 2.73 | 79 |
VOL-BL1K2C36 | 1.2 | 36 | 39.7 | 2270 | 5.05 | 84 |
VOL-BL1K5C24 | 1.5 | 24 | 73.5 | 2590 | 5.53 | 85 |
VOL-BL1K5C72 | 1.5 | 72 | 23.5 | 3200 | 4.48 | 89 |
VIEW MORE PLS CONTACT US >>>
Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.
What to do: Replace the fuse or reset the breaker.
Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.
Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.
Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.
Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.
Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.
Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.
Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.
Likely cause: Brushes are worn.
What to do: Verify brush length.
Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.
Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.
Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.