battery power 2.25KW 48V brushless dc motor 3000RPM
USD $200 - $690 /Unit
Min.Order:1 Unit
Motor type | Output | Voltage | Load | Speed | Rated Torque | Efficiency |
KW | V | A | RPM | N.m | % | |
VOL-BL075B48 | 0.75 | 48 | 16.98 | 3000 | 2.39 | 92 |
VOL-BL1K0C48 | 1 | 48 | 24.5 | 2500 | 3.82 | 85 |
VOL-BL1K2C24 | 1.2 | 24 | 63.3 | 4200 | 2.73 | 79 |
VOL-BL1K2C36 | 1.2 | 36 | 39.7 | 2270 | 5.05 | 84 |
VOL-BL1K5C24 | 1.5 | 24 | 73.5 | 2590 | 5.53 | 85 |
VOL-BL1K5C72 | 1.5 | 72 | 23.5 | 3200 | 4.48 | 89 |
VIEW MORE PLS CONTACT US >>>
Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.
What to do: Replace the fuse or reset the breaker.
Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.
Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.
Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.
Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.
Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.
Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.
Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.
Likely cause: Brushes are worn.
What to do: Verify brush length.
Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.
Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.
Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.