OTR-1903 Oxygen Permeability Tester
Negotiable /Unit
Min.Order:1 Unit
Systester Instruments Co., Ltd
ASTM Auto Servo Tensile Testing Machine Pharmaceutical Packaging
Water Vapor Permeability For Different Packaging Films Lab Testing Machine
Water Vapor Permeability Of Plastic Film Lab Testing Apparatus ASTM
Oxygen Permeability Of Contact Lenses High Pressure Testing Machine ASTM
Gas Permeability Of Silicone Rubber Vehicle Tire High Pressure Testing Machine Customized
Flexible Packaging Water Vapor Permeability Test Method Lab Testing Equipment
Application
OTR-1903 is based on the coulometric sensor method and available for the OTR test of flexible films, sheeting and packages.
Films:
Plastic films, aluminum foil, aluminized films, plastic composite films, paper-plastic composite films, coextruded films, aluminum foil composite films and many others.
Packages:
Plastic, rubber, paper, paper-plastic composite, glass and metal packages, e.g. red wine bottles, blister, various plastic bottles, Coke bottles, peanut oil packages, Tetra Pak materials, vacuum bags, metal three-piece cans, plastic packages for cosmetic, soft tubes for toothpaste, jelly and yogurt cups.
Features
Coulometric sensor method
Own technology
Film and package test
one piece specimen test
One-button test, test automatically in whole process
Multiple test modes optional
Data curves display
Computer control
Digital flow adjustment
Chamber with temperature sensor embedded in
Environment temperature and humidity sensor inside
Chambers with water bath temperature control technology
Unit based on embedded system,24bit Δ-Σ AD
Pressure, oxygen and temperature overload protection
Traceable reference film calibration
Supports DSM system (DSM, lab data management system)
Principles
Film:
The specimen is clamped between the upper and lower chamber, the upper chamber is purged by a oxygen stream, and the other side of specimen, lower chamber is purged by a stream of nitrogen, due to the effect of oxygen concentration gradient at two sides of the specimen, oxygen molecules will permeate through the specimen into the nitrogen side, penetrated oxygen molecules will be carried to the coulometric sensor which generates the proportional signal, so oxygen transmission rate and permeability coefficient will be obtained by calculating the sensor signal.
Package:
The package is mounted on the lower chamber, the outside of the package is air or a pure oxygen stream, the inside of the package is purged by a nitrogen stream, oxygen will permeate through the wall into the inside of the package, penetrated oxygen molecules will be carried to the coulometric sensor which generates the proportional signal, so oxygen transmission rate will be obtained by calculating the sensor signal.
Technical indexes
Test range:
Film: 0.01-6300 cm3/m2·d (Standard)
0.07-6,3000 cm3/m2·d (Optional)
Resolution: 0.001 cm3/m2·d
Package:
0.0001~62 cm3/pkg·d
Resolution: 0.00001 cm3/m2·d
Specimen amount: one piece
Temperature range: 5C – 95C (with temperature controller)
Temperature accuracy: ±0.1C
Humidity range: 0%RH,35%RH-90%RH,100%RH
Humidity accuracy: ±1%RH
Test area: 50cm2 Specimen size:
Film: size:>=150mm * 94mm; thickness: less 1mm
Package: max size: D120mm * 400mm
Carrier gas: 99.999% Nitrogen
Carrier flow: 0~20ml/min
Gas interface: 1/8inch
Power supply: AC 220V 50Hz
Dimension: 330mm(L) * 600mm(W) * 330mm(H)
Net weight: 28kg
Standard
ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, ISO 15105-2, GB/T 19789, JIS K7126-B, YBB 00082003
Configuration
Delivery: Main unit, computer, OX-TRANS software, tank regulator, PCIE card, communication cable, sample cutter, vacuum grease. Optional: Temperature controller, package fixtures, reference film, vacuum grease, sample cutter, DSM system.