VR-192GLA-LED-HW LED drive power aging car

VR-192GLA-LED-HW LED drive power aging car

USD $3000 - $4000 /Piece

Min.Order:1 Piece

Supply Ability:
100 Set / Sets per Month
Port:
SHENZHEN
Payment Terms:
T/T Other
Delivery Detail:
25 days

Quick Details View All >

Brand Name:
VURY
Place of Origin:
China
Model Number:
VR-192GLA-LED-HW

DONGGUAN VURY ELECTRONIC CO.,LTD

Business Type: Manufacturer
Dongguan Guangdong China
Main Products: ATE test equipment ,Power supply aging equipment

Product Details

VR-192GLA-LED-HW type power supply special aging car is mainly applicable to the aging test of power charger and LED drive power (isolated and unisolated). Its load body adopts programmed electronic load to ensure its stability and adjustability. The aging car is equipped with computer operation monitoring system, which can be set by PC to start and stop its work, and record relevant data for statistical analysis.

Aging car function

1.Load:VR-ETC75W-4L series electronic load;

2.Monitoring function:Equipped with PC, it is used to set aging technical parameters and product aging process, monitor the output voltage/current value of the tested product, and determine the aging good products;

3.Timing function:Aging time can be set in the range of 0.1-99h, with automatic timing function;

4Aging quantity 192PCS

5Working input voltage:220V

6Aging supply voltageelectric control cabinet can 90 v / 100 v / 120 v / 220 v / 240 v / 270 v switch;


Aging car technical parameter:

1Size1900(L)mmX2100(H)mmX650(W)mm

2Aging quantity192PCS

VR-192GLA-LED-HW adopts VR-ETC75W-4L series electronic load module for pulling, each aging car has 7 layers (the lower 3 layers are 180mm high; The upper four layers are 120mm high). 7 VR-ETC75W-4L load modules are installed on each layer, and a total of 49PCS of modules are installed. VR-ETC752 (G) -4L load module is divided into 4 channels load, CC, CV, LED, mode;

3The trolley is divided into aging area and load area. The product placement area is about 300mm wide. The product input interface adopts movable wiring strip (including fast clip) to facilitate the fast connection of large and small products. PCB output interface with parallel switch and fast clip, with LED indication;

40.5mm high temperature insulated epoxy board is laid on the pallet board to solve the defect of insulation skin shrinkage at high temperature

5.Aging car is equipped with PC computer, which is used to load monitoring software and control electric control part, can set and display aging current and product output voltage, and has the function of automatic detection and judgment of output voltage and current. Aging current/voltage can be set in layers, one aging car can aging products of seven different specifications at the same time;

6.LED is used to indicate the load status of each load group.

7Electronic load module has OCP (overload protection function);

Electronic load VR-ETC150W-2L main technical parameter

Aging electronic load VR - ETC75W - 4 L (G) is the main characteristic of switching load flexibility, can unattended operation process, save manpower, optional multimachine parallel function, meet the needs of high-power multiple sets of aging test, load current, soft start function load process will have any impact to the products tested, with stable performance not drift, master modularization, the most simple and convenient operating interface, use convenient adjustment, constant current and voltage (optional) load working mode, main power devices are imported to the United States and Japan, long life and high reliability, digitally stepless setting load current value; Ultra high brightness LED dual screen displays the set voltage and current value, intuitive and simple, high reliability OVP (over power protection function), fault free interval time (MTBF) up to 87000Hours.




      Function/Item

Technical parameter

remark

1

Load mode

CC/CV/LED/CR


2

DC input voltage range

2-400V

Automatically calculate the maximum power to prevent exceeding the setting range

DC input current range

0.05-8A


4  

Single load rated input power

75W

Over 75W, series and parallel are adopted

5

Maximum total input power

300W


6

Channel quantity

2 channel


7

Accuracy of current display

±3%


8

The current shows linearity

±3%


9

Overpower protection

 75W automatic protection

LED light flashing

10

Cooling way

Air cooling


11

Stepless temperature-controlled energy saving fan

80℃ self-closing

NTC temperature control

12

Load input power voltage

DC-12V


13

Control mode

Load module can be set by multiple groups and machine parameters


14

Operating power consumption

5W

Single

15

Life Time(MTBF

> above 80,000 hours


16

Work environment

-1050


17

Dimension



18

Weight



19

Control Mode

 


PC monitoring, data format (TXT,EXCEL) save, convenient query and download

Control function

Load product voltage monitoring

Can set the monitoring voltage range ±5%, can automatically determine the tested products

PC type





Contact Supplier

Mr. Ryan Liu Sales Manager Chat Now
Telephone
86-0769-22783291
Mobile
86-13925784741
Skype
ryanliu168
Address
Wanjiang Dongguan,Guangdong
Whatsapp
8613925784741

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Other Electrical Equipment
Categories
Hi~