Introduction
Liquid desiccant air conditioning with purified air function can be widely applied in air conditioning system which allow heat recovery, such as fresh air treatment for office, R&D building, transportation hubs, exhibition centre, hotels, apartment, hospital, and factories, ect; especially suitable for independent temperature and humidity control air conditioning system combined with other dry-table and equipment.
Application
Specification
Model (Txx-xx) | 03 | 04 | 05 | 06 | 08 | 10 | 12 | 15 | 20 | |
Power Source | 3PH-380V-50Hz | |||||||||
Fresh Air Rate | m3/h | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 | 20000 |
Cooling Capacity | kW | 65 | 85 | 108 | 128 | 172 | 215 | 255 | 325 | 430 |
Dehumidification | kg/h | 65 | 85 | 108 | 128 | 172 | 215 | 255 | 325 | 430 |
Heating | kW | 40 | 55 | 70 | 85 | 110 | 140 | 170 | 210 | 280 |
Moisture | kg/h | 20 | 25 | 30 | 40 | 50 | 65 | 80 | 100 | 130 |
Power | kW | 13.6 | 17.5 | 23.2 | 27.2 | 36.9 | 45.8 | 54.0 | 67.8 | 90.2 |
Noise | dB(A) | 61 | 61 | 62 | 62 | 63 | 63 | 63 | 63 | 64 |
Compressor type | Full Closed Scroll Compressor | |||||||||
Throttle type | The Balance Type Thermal Expansion Valve | |||||||||
Refrigerant type | R22/R407C | |||||||||
Filtration grade | Primary (G4) | |||||||||
Supply/Exhaust air type | The Outer Rotor Centrifugal Fan | |||||||||
over-bottom pressure | Pa | 150 | 150 | 180 | 180 | 210 | 240 | 250 | 300 | 350 |
Weight | kg | 2050 | 2200 | 2650 | 3080 | 3580 | 4350 | 5250 | 6010 | 6820 |
Notes: 1.Nominal cooling and dehumidification working conditions: fresh air dry bulb temperature 36℃, relative humidity 60%,; returned air dry bulb temperature 26℃, relative humidity 60%; supply air dry bulb temperature 18℃, wet bulb temperature 13.3℃. 2. Nominal heating and humidification working conditions: fresh air dry bulb temperature -5℃, relative humidity 50%,;returned air dry bulb temperature 20℃, relative humidity 50%; supply air dry bulb temperature 18℃, wet bulb temperature 13.7 3. The above section and setting are only for reference. Please choose and adjust based on actual project requirement, or provided y customer.
Dimension Drawing
1,AHLD-Txx-03,04,05,06,08,10,12
2,AHLD-Txx-15,20
Model (Txx-xx) | 03 | 04 | 05 | 06 | 08 | 10 | 12 | 15 | 20 | ||
L | mm | 3000 | 3000 | 3100 | 3100 | 3200 | 3200 | 3400 | 3200 | 3200 | |
W | mm | 1400 | 1400 | 1850 | 1850 | 2250 | 2250 | 2250 | 4800 | 4800 | |
H | mm | 2200 | 2250 | 2400 | 2400 | 2400 | 2550 | 2800 | 2400 | 2550 | |
Supply Air Outlet | A | mm | 310 | 363 | 406 | 406 | 467 | 467 | 467 | 496 | 496 |
B | mm | 275 | 275 | 338 | 338 | 420 | 420 | 420 | 445 | 445 | |
Amount | 1 | 2 | |||||||||
Exhaust Air Outlet | C | mm | 310 | 363 | 406 | 406 | 467 | 467 | 467 | 496 | 496 |
D | mm | 275 | 275 | 338 | 338 | 420 | 420 | 420 | 445 | 445 | |
Amount | 1 | 2 | |||||||||
Fresh Air Outlet | E | mm | 700 | 700 | 900 | 900 | 1300 | 1300 | 1300 | 1300 | 1300 |
F | mm | 550 | 650 | 550 | 700 | 700 | 800 | 900 | 700 | 800 | |
Amount | 1 | 2 | |||||||||
Return Air Outlet | J | mm | 1100 | 1100 | 1500 | 1500 | 1900 | 1900 | 1500 | 1900 | 1900 |
K | mm | 350 | 450 | 450 | 500 | 500 | 550 | 650 | 500 | 550 | |
Amount | 1 | 2 |