Introduction:
Using the imported Capelec movement from France, using the principle of non-dispersive infrared absorption, the HC, CO, and CO2 in the exhaust gas of gasoline vehicles are measured through microcomputer analysis. The concentration of O2 and NO can be measured by electrochemical principle and the exhaust gas of diesel vehicles can be accurately measured. The content of various gas components.
Applicable to environmental protection departments, mining related enterprise departments, automobile and motorcycle manufacturing plants, engine manufacturing companies, automobile maintenance companies, public security inspection stations, traffic inspection stations, and research departments such as vehicle maintenance, motor vehicle inspection, road inspection, and scientific research vehicles Exhaust gas composition test.
Features:
1.Based on the national GB/T18285-2005 standard, upgrades and improvements are made to detect the concentrations of gaseous components emitted by diesel vehicles and meet the JJG688-2007 metrological verification procedures that meet the national I-level or higher metrological verification standards.
2.Using the original imported French Capelec movement, adopting the principle of non-dispersive infrared absorption method, measuring the HC, CO, and CO2 in the exhaust gas of the vehicle through microcomputer analysis, and measuring the concentrations of O2 and NO using the electrochemical principle.
3.Add diesel particulate emission special particulate filtering device can be seen to reduce the damage of particulate pollutants on the import movement, more accurate measurement of diesel gas emissions in a variety of gas component content.
4.With idle, dual idle test function, you can choose matching oil temperature and speed measurement.
5.Configuration 7-inch high-brightness LCD display, multi-language operation menu support.
6.Automatically calculated, showing the excess air coefficient λ value.
7.Equipped with RS-232C digital serial communication interface, easy to network.
8.With more than 500 sets of data storage, review functions.
9.Equipped with a built-in printer
10.Configurable automotive power inverter, convenient vehicle exhaust inspection.
Technical Parameters:
1.The use of environmental conditions:
Temperature:0~40°C
Humidity: no more than 95%
Atmospheric pressure: 70.0 to 106kPa
Power supply: AC220V±10%; 50Hz±1Hz
2.The measurement range:
CO: 0 to 15 10-2 vol
HC: 0 to 10000 10-6vol
CO2: 0 to 20 10-2 vol
O2: 0~25 10-2 vol
NO: 0 to 5000 10-6 vol
λ: 0.8-1.2 (RMS)
Engine Speed (RPM): 0~9990 rpm (optional)
Oil temperature: 0°C~150°C (optional)
3.Indication error:
Low concentration absolute error: Relative error:
CO: ±0.06% vol CO:±5%
HC: ±12ppm vol HC: ±5%
CO2: ±0.5% vol CO2:±5%
O2: ±0.1% vol O2:±5%
NO: ±25ppm vol NO:±4%
4.Warm-up time: 10 minutes
5.Weight: 10kg
6.Volume: Host 420*320*250(mm)