SV-YQ car-diesel dual-use vehicle exhaust gas detector
USD $2,501 - $3,127 /Unit
Min.Order:1 Unit
Lixian Instrument Scientific Co., Ltd.
Introduction:
The combination of SV-5Q and SV-5Y can measure the exhaust components of five groups of gasoline vehicles and the smoke of diesel vehicles at the same time, as well as measure the emission of liquefied petroleum gas (LPG) ), Compressed natural gas (CNG) diesel and gasoline and other vehicles.
SV-YQ automobile exhaust gas detector used to measure the concentration of HC, CO, CO2, O2, NO in exhaust gas of motor vehicles and the smoke exhaust smoke, with the idle speed and double idle speed test function of gasoline vehicles Configure the power inverter (with the vehicle to test the oil temperature and speed of the function).
Features:
1. Used to measure the concentration of HC, CO, CO2, O2 and NO in vehicle exhaust gas and smoke smoke
2. with opacity and optical absorption coefficient of two readings
3. with free acceleration experiment and transient measurement function, and automatically process the test data and display the measurement results
4. with the idle speed of gasoline cars, dual idle speed test function
5. LCD (liquid crystal) screen display, multi-language user interface
6. automatic calculation, show the value of excess air coefficient λ
7. equipped with RS-232C digital serial communication interface for easy networking
8. with 500 sets of data storage, configurable printer
9. vehicles that measure fuels such as liquefied petroleum gas (LPG), compressed natural gas (CNG) diesel and gasoline
10. in line with GB18285-2005 and GB3847-2005 new national standard requirements
11. configurable power inverter (with the vehicle to test the oil temperature and speed of the function)
Technical Parameters:
asuring range
CO: 0 to 10% CO2: 0 to 20%
HC: 0 to 10000 ppm O2: 0 to 25%
NO: 0-5000 ppm N: 0-99.9%
K: 0 ~ 16.06m-1
Oil temperature: 0 ~ 150 ℃
Speed: 0 ~ 10000rpm
2. zero drift
CO: ± 0.06% CO2: ± 0.5%
HC: ± 30ppm O2: ± 0.5%
NO: ± 30ppm N: ± 2.0%
CO: 0.01% CO2: 0.1%
HC: 1 ppm O2: 0.01%
NO: 1 ppm N: 0.1%
K: 0.01m-1 Oil temperature: 0.1 ℃
Speed: 1 rpm
3. showing the error
CO: ± 5% CO2: ± 5%
HC: ± 5% O2: ± 5%
NO: ± 5% N: ± 2.0%
Oil temperature: ± 2 ℃ Speed: ± 1%
4. weight
Measuring unit 7.5kg Control unit 6kg
5. bare metal size
Host 545 * 310 * 190mm
Auxiliary 400 * 240 * 380mm
6. display
Large-screen LCD display
7. sampling methods
Double sampling probe, sampling gasoline and diesel exhaust respectively.