CW-700S TOC analyzer
USD $9,800 - $12,600 /Unit
Min.Order:1 Unit
Lixian Instrument Scientific Co., Ltd.
The CW-700S is a compact instrument. The main components are installed on the mainframe. Before the measurement, the instrument needs to connect the gas path and prepare reagents. The instrument is controlled by specialized software installed on an external computer for data processing such as measurement, calibration, and printing. How it works: The principle of UV-persulphate oxidation-NDIR detection is used. One sample was fully oxidized and decomposed to CO2 by UV and persulfate, and the other sample was decomposed by inorganic reagents to CO2. CO2 is dried and decontaminated by a carrier gas and then passed into a non-dispersive infrared detector (NDIR) to determine the concentration of carbon in the sample.
Features:
1 Meet the requirements of the EP, USP, and 2015 editions of the Chinese Pharmacopoeia;
2 three detection modes: TC, TIC, TOC, NPOC, carried out in the same reactor;
3 High-reflective gold-plated gas chamber, high-concentration infrared light source and high-sensitivity infrared detectors ensure excellent performance of the NDIR. 4 Measurement of ppb-level data has sufficient sensitivity and accuracy.
5 precision electromagnetic metering pumps, to ensure the accuracy and stability of the injection volume;
6 dual-tube electronic condensation dehydration technology;
7 Detection curve can be seen in real time, more intuitive;
8 multiple real-time self-monitoring functions for temperature, pressure and flow;
9 It is possible to formulate curves according to the range and meet the measurement of any water sample;
10 optional online module for online monitoring;
11 Optional auto sampler, unattended, saving manpower and time.
Technical Parameters
Analytical Method: UV Persulfate Oxidation - NDIR Detection Theory
Detectable items: TC, IC, TOC, NPOC
TOC detection range: 0.001~100.0mg/L
TOC detection accuracy: 0.001mg/L
TOC accuracy error: ≤±5%
Injection volume: 50 to 6000ul
Analysis time: 3~8min
Repeatability error: ≤3%
Zero drift: ≤±2%/D
Range drift: ≤±2%/D
Test Conditions Oxidizer: Sodium persulfate solution
Acid reagent: phosphoric acid solution
Carrier gas: high purity nitrogen (carbon dioxide free air)
Environmental requirements Ambient temperature: 0 to 40°C
Relative humidity: ≤85%
Power Requirements Power Supply: 220V AC≤±10% 50Hz
Power: 150W
Basic size: 38cm×30cm×32cm
Weight: 20kg
Dear customer,
We ,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history .
Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing, bioscience,medical apparatus and instruments,internet technology and some frontier science.
Through a long-time development,we own a national resources system of various professional talents , abundant supply for various components &parts and special materials, full producing &processing equipments , strong Technological standardization and a complete quality assurance system.
If you need OEM or ODM in manufacturing ,scientific research , market development and or you want to build your own brand in your country, it’s our honor to cooperate with you.In this way ,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba
We firmly believe that science and technology is no boundaries Our mission is to make every effort to contribute to all humanity.
|