WFX130A Flame/Graphite Furnace Atomic Absorption Spectrophotometer

WFX130A Flame/Graphite Furnace Atomic Absorption Spectrophotometer

USD $14,300 - $31,500 /Set

Min.Order:1 Set

Supply Ability:
15 Set / Sets per Month
Port:
shanghai
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
BFRL-S
Place of Origin:
Shaanxi, China
Model Number:
WFX130A
Size:
102X49X54cm
Weight:
unpacked 80kg
Measurement Range:
190-900nm

Lixian Instrument Scientific Co., Ltd.

Business Type: Distributor/Wholesaler
Main Products: Tester , , ,

Product Details

WFX110A/120A/130A Flame/Graphite Furnace Atomic Absorption Spectrophotometer

Features:

1    Innovated rich oxygen air-acetylene flame analysis technique(WFX-110A):

The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temeperature is continuously adjustable between 2300-2950℃, with makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame will not pollute the environment and is not harmful to human bodies. It's break-through in flame AAS analysis

2   Integrated flame/graphite furnace atomization system, changeable with flame emission burner

2.1 Automatically controlled changeover of the integrated flame and graphite furnace atomizer featuring easy operation and time

      saving eliminates human labor.

2.2 A flame emission burner head can be installed to perform flame emission analysis to Alkali metals as K, Na etc.(WFX-

      110A/120A)

3   Accurate fully automated control system

3.1 Automatic multi-lamp turret, automatic adjustment of lamp current and optimization of light beam position

3.2 Automatic wavelength scanning and peak picking

3.3 Automatic spectral bandwidth changing

3.4 Automatic changeover between flame and graphite furnace operation, automatic optimization of position parameters and

      automatic ignition

4    Reliable fully automatic graphite furnace analysis

4.1 Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction

      technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity. The temperature

      control accuracy is less than 1%

4.2 Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact

5   Perfect safety protection measures

5.1 Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in

      flame system

5.2 Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling wate supply and

      over-heating in graphite furnace system

6   Advance and reliable electronic design

6.1 Adopting large-scale programmable logic array and Inter I2C bus technology

6.2 European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system

7   Easy and practical analysis software

7.1 Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and

      optimization

7.2 Automatic display of measured data, automatic calculation and analytical result automatic print out.

 

 

Technical parameters:

 

Main Specification

Wavelength range

190-900nm

Wavelength accuracy

Better than ±0.25nm

Resolution

Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.

Baseline stability

0.004A/30min

Background correction

The D2 lamp background correction capability at 1A is better than 30 times

The S-H background correction capability at 1.8A is better than 30 times.( only for WFX-110A/120A)

 

Hollow Cathode Lamps

Lamp turret

6-lamp turret (WFX-110A/120A), 4-lamp turret (WFX-130A); Auto-alignment, fully automated scan and peak-picking.

Lamp current adjustment

400Hz square wave pulse

Wide pulse current: 0~25mA,
Narrow pulse current: 0~10mA

Lamp power supply mode

400Hz square wave pulse;

100Hz narrow square wave pulse+400Hz wide square wave pulse (WFX-110A/120A)

Optical System

Monochomator

Single beam, Czerny-Turner design grating monochromator

Grating

1800 l/mm

Focal length

277mm

Blazed Wavelength

250nm

Spectral Bandwidth

0.1nm, 0.2nm, 0.4nm, 1.2nm, automatic change

Flame Atomizer

Burner

10cm single slot all-titanium burner

Spray chamber

Corrosion resistant all-plastic spray chamber

Nebulizer

High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min

Emission burner provided with WFX-110A/120A

Graphite Furnace

Temperature range

Room temperature~3000ºC

Heating rate

2000℃/s

Graphite tube dimensions

28mm(L)×8mm(OD)

Characteristic mass

Cd≤0.5 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g

Precision

Cd≤3%, Cu≤3%, Mo≤4%

Detection and Data Processing System

Detector

R928 Photomultiplier with high sensitivity and wide spectral range.

Software

 Windows operating system

Analytical method

Working curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content.

Repeat times

Maximum 20 times of repeat measurement, automatic calculation of mean value, standdard deviation and relative standard deviation.

Multi-task Functions

Sequential measurement for multi-element determination in one sample

Condition reading

With model function

Result printing

Measurement data and final analytical report printout, editing with Excel

Standard RS-232 serial port communication

Characteristic Concentration and Detection Limit

Normal Air-C2H2 flame

Oxygen-rich Air-C2H2 flame

Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;

Ba:  Characteristic concentration ≤ 0.22mg/L

Al:   Characteristic concentration ≤ 0.4mg/L

Function Expansion

Hydride vapor generator can be connected for hydride analysis

Dimensions and weight

Main unit

102×49×54cm, unpacked 80kg

Graphite furnace

42×42×46cm, unpacked 50kg

 

 

 WFX130A Flame/Graphite Furnace Atomic Absorption Spectrophotometer

 

 

Dear customer,

We ,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history .

Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing, bioscience,medical apparatus and instruments,internet technology and some frontier science.

Through a long-time development,we own a national resources system of various professional talents , abundant supply for various components &parts and special materials, full producing &processing equipments , strong Technological standardization and a complete quality assurance system.

If you need OEM or ODM in manufacturing ,scientific research , market development and or you want to build your own brand in your country, it’s our honor to cooperate with you.In this way ,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba

We firmly believe that science and technology is no boundaries

Our mission is to make every effort to contribute to all humanity.

Contact Supplier

Mobile
12540601738

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Optical Instruments > Spectrometers
Categories
Hi~