GC-9801 Gas chromatography/GC Analyzer
USD $5.00 - $15.00 /Set
Min.Order:1 Set
GC-9801 Gas chromatography
Function:
Gas chromatography carries out the quantitative analysis and peculiar smell testing for residual solvent on food packaging cases after printing;
Test the pureness and quality of organic solvents.
Techinical Parameter
Item | GC 9801 |
Hydrogen flame ionization detector (FID) | M≤1×10-11 G/S |
Thermal conductivity detector (TCD) | S≥5000mv.ml/mg (benzene) |
Electron capture detector (ECD) | M≤2×10-13g/ml (r-666) |
Flame-photometric detector (FPD) | Ms≤5×10-11g/sec (thiophene) Mp≤1×10-11g/sec (1605) |
Nitrogen and phosphorous detector (NPD) | Mn:1×10-13g/sec Mp:1×10-13g/sec |
Temperature | 10~400°C |
Temperature percision | ≤0.1°C |
Temperature rise speed | 0.1~40°C/min |
Features:
1.With higher ratio of function and reasonable price, economic and efficient
2.The design of the cellular integral structure is convenient for installation.
3.It can be connected to the chromatogram data work station so as to greatly improve the working efficiency.
4.With FID detector
5.With the flexible design of the packed column and capillary column injection ports.
6.Packed column and capillary column sample injectors can be selected as per actual situations. Wide column box (300×300×200mm)
7.In order to meet complicated analytic task, it makes use of various chromatographic columns so as to offer convenience and widen the range of the analytic samples. The advanced noise suppression system can fully eliminate the fan noise under the chromatogram working state, so as to provide you a comfortable and quiet working atmosphere.
8.The sampling device is completely vitrified with two modes of rapid vaporizing and column sample injection.
9.Bran-new pressure stabilization and various air circuit system
10.The air circuit has three different kinds of forms: Single, double and triple. It can match six-way valve, blow back, and precut equipment and so on according to the users’ demands. It adopts new type pressure regulation system to ensure the re-productivity of equipment.
11.Reforming furnace can be equipped to implement microanalysis of CO and CO2.
12.Cracking furnace can be equipped to do double eight-step temperature rise with microcomputer control, man-machine conversation and simple application.
13.Advanced temperature control system
14.Adopt microcomputer control and man-machine conversation to indicate various needed temperatures of the temperature column box.
15.Column box temperature control scope: (room temperature +10°C) - 400°C, eight-step temperature rise.
The speed is 0 - 30°C/min (increase 0.1°C/min), and the temperature control precision is 0.1%.
The control point number is eight points of A type with control scope (room temperature +10°C) - 400°C.
16.Overheat protection function
It can freely set temperature within 400°C with software program protection, and the hardwired connection adopts dual fail-safe design
Operation Interface
Service
1: One year guarantee and all lifetime techinical support
2: USA, Australia Aisa Local agent for service
3 Speedy reply, 12hrs response to customer questions
4 Software free update
5. Minor maintenance ---parts ship within 24 hrs
6 Major maintenance---Technical will be sent within 15 days
Certificate:
Our customer:
Our Laboratory:
Our team: