Neware 5V20mA electrolytes cycler life tester
USD $2000 - $3000 /Set
Min.Order:1 Set
Neware Technology Limited Company
Neware is a leading manufacturer of battery testing system manufacturer for 20 years in China.
Our equipment provide DCIR,pulse,cycle life,capacity test and so on.
Technical Specification:
BTS-5V50mA | Battery Testing System | |||||||||||||||
Model: | BTS- | 5 | V | 50 | mA | Material Code: | CT-4008 | -5V50mA | - | N | - | S1 | ||||
Description | Product Specification | |||||||||||||||
AC Input | AC 110V±10% 50Hz | |||||||||||||||
Power | 3544 | mW | ||||||||||||||
Resolution | AD: 16bit; DA: 16bit | |||||||||||||||
Input Impedance | ≥1MΩ | |||||||||||||||
Voltage | Measuring Range | 25mV~5V | ||||||||||||||
Discharge Min Voltage | 10mV | |||||||||||||||
Accuracy | ± 0.05% of FS | |||||||||||||||
Stability | ± 0.05% of FS | |||||||||||||||
Current | Range | Charge: 0.1mA~50mA Discharge: 0.1mA~50mA | ||||||||||||||
Accuracy | ± 0.05% of FS | |||||||||||||||
Stability | ± 0.05% of FS | |||||||||||||||
Power | Output Power Per Channel | 250mW | ||||||||||||||
Stability | ± 0.1% of FS | |||||||||||||||
Time | Rise Time | 1ms (0~Full Range) | ||||||||||||||
Step Time | ≤ (365*24) hour/step | Time Format 00:00:00:000 (h:min:s:ms) | ||||||||||||||
Data Acquisition | Intervals | Time interval Δt:(100ms~60000s) | ||||||||||||||
Voltage interval ΔU: (10mV~5V) | ||||||||||||||||
Current interval ΔI: (0.1mA~50mA) | ||||||||||||||||
Frequency | 10Hz | |||||||||||||||
Charge | Modeof Operation | CCC, CVC, CC & CVC, CPC | ||||||||||||||
End Conditions | Voltage, Current, Test Time, Capacity | |||||||||||||||
Discharge | Modeof Operation | CCD, CPD, CRD | ||||||||||||||
End Conditions | Voltage, Current, Test Time, Capacity | |||||||||||||||
Pulse | Charge | CCC | ||||||||||||||
Discharge | CCD | |||||||||||||||
Min Pulse Width | 500ms | |||||||||||||||
Automated Switch | Automated switch from charge to discharge for each pulse | |||||||||||||||
End Condition | Voltage, Test Time | |||||||||||||||
Cycle | Cycles | 65535 | ||||||||||||||
Steps | 254 | |||||||||||||||
Nested Function | Max three levels of loops | |||||||||||||||
Protective Function | Power-off data protection | |||||||||||||||
Off-line Operating | ||||||||||||||||
User-defined safety(upper and lower)tolerance of current, voltage and delay time | ||||||||||||||||
Channel Features | Independent pairs of closed loop for constant current source and constant voltage source | |||||||||||||||
Channels | Independent control | |||||||||||||||
Detection and Sampling | 4-wire Connecting | |||||||||||||||
Noise Density | <85dB | |||||||||||||||
Data Management | MYSQL Database | |||||||||||||||
Communication Means | TCP/IP Protocol | |||||||||||||||
Export Formats | EXCEL, TXT, Graph | |||||||||||||||
Communication Interface | Ethernet Port | |||||||||||||||
Number of Channels Per Cabinet | 8 | |||||||||||||||
Operating Environment | ||||||||||||||||
Description | Product Specification | |||||||||||||||
Operating Temperature | 0ºC~40ºC | |||||||||||||||
Storage Temperature | -10ºC~50ºC | |||||||||||||||
Operating Humidity | ≤70% RH | |||||||||||||||
Storage Humidity | ≤80% RH |
Warraty: 1 year
Delivery: 7days after deposit
Contact information:
Emily Zhang