Neware Electrical Motor batteries pack charge/discharge instrument
USD $8000 - $10000 /Set
Min.Order:1 Set
Neware Technology Limited Company
Order cllassification:
The price for the battery tester above only for reference, pls contact me.
About the measurement:According to the different range of voltage and current for each type batteries, pls contact me.
About the clamps:Based on the type of the batteries
BTS-5V6A is an eight-channel battery analyzer to analyze small coin cells and cylindrical batteries from 30 mA to 6A, up to 5V.
Each channel of the analyzer has independent constant-current and constant-voltage source, which can be programmed and controlled by computer software.
This system provides most applications in battery testing fields such as electrode materials research, battery performance test, small-scale battery formation, capability grading, battery pack testing, etc.
Technical Specification:
IGBT-200V300A | ||||||||||||
Model: | IGBT- | 200 | V | 300 | A | Battery Testing System | Material Code: | CE-7001 | - | 200V300A | ||
Description | Product Specification | |||||||||||
AC Input | AC 380V±10% 50Hz | |||||||||||
Single-phase Power | 20 | KW | ||||||||||
Single-phase Current | 101 | A | ||||||||||
Input Power | 67 | KW | ||||||||||
Resolution | 100ms | |||||||||||
Voltage | Range | 1000mV~200V | ||||||||||
Accuracy | ± 0.1% of FS | |||||||||||
Stability | ±0.1% of FS | |||||||||||
Current | Range | Charge: 15A~300A Discharge: 15A~300A | ||||||||||
Accuracy | ±0.1% of FS | |||||||||||
Stability | ± 0.1% of FS | |||||||||||
Power | Output Power Per Channel | 60KW | ||||||||||
Stability | ±0.2% of FS | |||||||||||
Time | Rise Time | 10ms(10%FS~90%FS) | ||||||||||
Step Time | ≤ (365*24) hours/step | Time Format 00:00:00:00 (h:min:s:ms) | ||||||||||
Aux Channel (optional ) | Aux Input | Temperature,Voltage | ||||||||||
Temperature Range | -25ºC~110ºC | |||||||||||
Temperature Accuracy | ±1ºC | |||||||||||
Temperature Resolution | 0.1ºC | |||||||||||
Voltage Range | -5v~5v | |||||||||||
Voltage Accuracy | ± 0.1% of FS | |||||||||||
Data Acquisition | Intervals | Time Interval Δt: (1s~60000s) | ||||||||||
Voltage Interval ΔU: (10V~200V) | ||||||||||||
Current Interval ΔI: (15A~300A) | ||||||||||||
Frequency | 10Hz | |||||||||||
Charge | Modes of Operation | CCC, CVC, CC&CVC | ||||||||||
End Conditions | Main Channel: Voltage, Current, Test Time, Capacity | |||||||||||
Aux Channels: Temperature,Voltage | ||||||||||||
Discharge | Modes of Operation | CCD, CPD | ||||||||||
End Conditions | Main Channel: Voltage, Current, Test Time, Capacity | |||||||||||
Aux Channels: Temperature,Voltage | ||||||||||||
Cycle | Cycles | 1~65535 | ||||||||||
Steps | 254 | |||||||||||
Nested Function | Max three levels of loops | |||||||||||
Protective Function | Power-off data protection | |||||||||||
Off-line Operating | ||||||||||||
Main Channels: user-defined safety (upper and lower) tolerance of current, voltage and delay time | ||||||||||||
User-defined safety (upper and lower) tolerance of temperature and voltage | ||||||||||||
Channel Features | Independent pairs of closed loop for constant current source and constant voltage source | |||||||||||
Energy Regeneration | Regenerative Discharge Energy to Power Grid | |||||||||||
Channels | Independent control | |||||||||||
Noise Density | <85dB | |||||||||||
Data Management | MYSQL Database | |||||||||||
Communication Protocol | TCP/IP | |||||||||||
Export Formats | EXCEL, TXT, Graph | |||||||||||
Communication Interface | Ethernet port |
Warraty: 1 year
Delivery: 7days after deposit
Contact information:
Emily Zhang