NO-AE High Concentration Nitric Oxide Sensor (NO Sensor)

NO-AE High Concentration Nitric Oxide Sensor (NO Sensor)

USD $40 - $120 /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Port:
HK
Payment Terms:
T/T PayPal

Quick Details View All >

Brand Name:
Alphasense
Place of Origin:
United Kingdom
Model Number:
NO-AE
Usage:
Gas Sensor
Theory:
Other, Electrochemical Gas Sensor
Output:
Analog Sensor

Shenzhen Isweek Ltd.

Business Type: Distributor/Wholesaler
Main Products: Gas Sensor ,UV Sensor ,Humidity Sensor ,Pressure Sensor ,Ultrasonic Sensor ,Wind Speed sensor ,Liquid Level Sensor

Product Details

NO-AE Nitric Oxide Sensor (NO Sensor) Description
Alphasense Nitric Oxide gas sensors operate using proven fuel cell technology.

NO-AENitric Oxide Sensor size:
20mm diameter, the industry standard size for portable gas detectors

The NO range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 200 parts per billion (ppb) whilst giving linear outputs to as high as 250ppm. The sensors are suitable for inclusion in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analysers.

Alphasense NO sensors provide a significant improvement in stability of response to transient relative humidity changes.

The NO sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification.

NO-AE Nitric Oxide Sensor NO Sensor PERFORMANCE
Sensitivity
nA/ppm in 250ppm NO
40 to 80
Response time
t90 (s) from zero to 250ppm NO
<75
Zero current
ppm equivalent in zero air
0 to 15
Resolution
RMS noise (ppm equivalent)
<1
Range
ppm NO limit of performance warranty
5,000
Linearity
ppm error at full scale, linear at zero and 1000ppm NO
<250
Overgas limit
maximum ppm for stable response to gas pulse
10,000



NO-AE Nitric Oxide Sensor NO Sensor LIFETIME
Zero drift
ppm equivalent change/year in lab air
nd
Sensitivity drift
% change/year in lab air, monthly test
nd
Operating life
months until 80% original signal (24 month warranted)
> 24



NO-AE Nitric Oxide Sensor NO Sensor ENVIRONMENTAL
Sensitivity @ -20°C
% (output @ -20°C/output @ 20°C) @ 50ppm
65 to 90
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 50ppm
103 to 112
Zero @ -20°C
ppm equivalent change from 20°C
<0 to -3
Zero @ 50°C
ppm equivalent change from 20℃
<10 to 40



NO-AE Nitric Oxide Sensor NO Sensor CROSS SENSITIVITY
H2S  sensitivity
% measured gas @ 20ppm H2S
<50
NO2  sensitivity
% measured gas @ 50ppm NO2
<20
Cl2    sensitivity
% measured gas @ 10ppm Cl2
<25
SO2   sensitivity
% measured gas @ 20ppm SO2
<5
CO     sensitivity
% measured gas @ 400ppm CO 
<0.1
H2     sensitivity
% measured gas @ 400ppm H2
<0.1
C2H4 sensitivity
% measured gas @ 400ppm C2H4
<0.1
NH3   sensitivity
% measured gas @ 20ppm NH3
<0.1
CO2   sensitivity
% measured gas @ 5% Vol CO2
<0.1



NO-AE Nitric Oxide Sensor NO Sensor KEY SPECIFICATIONS
Temperature range
°C
-30 to +50
Pressure range
kPa
80 to 120
Humidity range
% rh continuous
15 to 90
Storage period
months @ 3 to 20°C (stored in sealed pot)
6
Bias voltage
mV (working electrode potential is above ground)
+300
Load resistor
Ω (recommended)
10 to 47
Weight
g
< 6


Matched Transmitter board for NO-AE NO Sensor

4-20mA Digital Transmitter Board
   • Factory calibration, custom-set for immediate use
   • Digital zero, sensitivity and temperature compensation
   • Digital and 4-20mA output
   • Biased or unbiased operation
   • Calibration and range change


Contact Supplier

Ms. Ms Rita yu Sales Chat Now
Telephone
86-755-83289036
Mobile
86-15216024218
Fax
86-755-83289052
Skype
Isweek_Rita
Address
16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan Shenzhen,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electronic Components & Supplies > Active Components > Sensors
Categories
Hi~