Neware 10V10A DCIR with Pulse battery tester
USD $2000 - $3000 /Set
Min.Order:1 Set
Neware Technology Limited Company
NEWARE offers charge/discharge battery testing systems ranging from μA signal cell applications up to 300kw packs.
Application:
1,Coincell,cylindrical,prismatic,&flat cell testing.
2,Basic cycling,electrochemical experiment,and advanced real-world simulations.
3,Battery packs and modules of all sizes.
4,Any battery chemistry including lithium,silicon,sulfur,lead acid,nickel,&more.
Technical Specification:
BTS-5V30A | Battery Testing System | |||||||||||||||
Model: | BTS- | 5 | V | 30 | A | Material Code: | CT-4016 | -5V30A | - | NA | - | |||||
Description | Product Specification | |||||||||||||||
AC Input | AC 220V±10% 50Hz | |||||||||||||||
Power | 4253 | W | ||||||||||||||
Resolution | AD: 16bit; DA: 16bit | |||||||||||||||
Impedance Input | ≥1MΩ | |||||||||||||||
Voltage | Measuring Range | 25mV~5V | ||||||||||||||
Discharge Min Voltage | 2.5V | |||||||||||||||
Accuracy | ± 0.1% of FS | |||||||||||||||
Stability | ± 0.1% of FS | |||||||||||||||
Current | Range | Charge: 150mA~30A Discharge: 150mA~30A | ||||||||||||||
Accuracy | ± 0.1% of FS | |||||||||||||||
Stability | ± 0.1% of FS | |||||||||||||||
Power | Output Power Per Channel | 150W | ||||||||||||||
Stability | ± 0.2% of FS | |||||||||||||||
Time | Rise Time | 20ms (10%FS~90%FS) | ||||||||||||||
StepTime | ≤ (365*24) hour/step | Time Format 00:00:00 (h:min:s) | ||||||||||||||
Data Acquisition | Intervals | Time interval Δt: (1s~60000s) | ||||||||||||||
Voltage interval ΔU: (10mV~5V) | ||||||||||||||||
Current interval ΔI: (60mA~30A) | ||||||||||||||||
Frequency | 1Hz | |||||||||||||||
Charge | Modes of Operation | CCC, CVC, CC & CVC, CPC | ||||||||||||||
End Conditions | Voltage, Current, Test Time, Capacity | |||||||||||||||
Discharge | Modes of Operation | CCD, CPD, CRD | ||||||||||||||
End Conditions | Voltage, Current, Test Time, Capacity |
Cycle | Cycles | 65535 | ||||||||||||||
Steps | 254 | |||||||||||||||
Nested Function | Max three levels of loops | |||||||||||||||
Protective Function | Power-off data protection | |||||||||||||||
Off-line Operating | ||||||||||||||||
User-defined safety (upper and lower) tolerance of current, voltage and delay time | ||||||||||||||||
Reverse-connecting protection | ||||||||||||||||
Channel Features | Independent pairs of closed loop for constant current source and constant voltage source | |||||||||||||||
Channels | Independent control | |||||||||||||||
Detection and Sampling | 4-wire Connecting | |||||||||||||||
Noise Density | <85dB | |||||||||||||||
Data Management | MYSQL Database | |||||||||||||||
Communication Means | TCP/IP Protocol | |||||||||||||||
Exports Formats | EXCEL, TXT, Graph | |||||||||||||||
Communication Interface | Ethernet Port | |||||||||||||||
Number of Channels Per Cabinet | FALSE | |||||||||||||||
Operating Environment | ||||||||||||||||
Description | Product Specification | |||||||||||||||
Operating Temperature | 0ºC~40ºC | |||||||||||||||
Storage Temperature | -10ºC~50ºC | |||||||||||||||
Operating Humidity | ≤70% RH | |||||||||||||||
Storage Humidity | ≤80% RH |
Warraty: 1 year
Delivery: 7days after deposit
Contact information:
Emily Zhang