Ptfe Sealing Ls-g02-2ba-25-en-650 1 Inch Steam Solenoid Valve
Negotiable
Min.Order:0
Mev20blef6b160 Firedamp Gas Steam Solenoid Valve Little Friction
Double Electrical Control Steam Solenoid Valve 1/2 Inch Kso-g02-81cp-30-cle
Yuken Steam Solenoid Valve Ls-g02-2aa-30 Double Electrical Control
Multi Function Edpm Sealing Ls-g02-2aa-30 Steam Solenoid Valve
Elektrogas Kso-g02-91ca-30-cle Steam Solenoid Valve Coil Connectors
installation precautions
(1) When installing, please pay attention to the arrow on the valve body should be consistent with the flow direction of the medium;
(2) Do not install in places where there is direct dripping or splashing water and the solenoid valve should be installed vertically.
(3) The solenoid valve should ensure normal operation within the fluctuation range of 15%-10% of the rated voltage of the power supply voltage.
(4) After the solenoid valve is installed, there must be no reverse pressure difference in the pipeline. It needs to be powered on several times to make it suitable for use.
(5) Thoroughly clean the pipe before installing the solenoid valve. The medium to be passed should be free of impurities. Install the filter in front of the valve.
(6) When the solenoid valve fails or is cleaned, a bypass device should be installed to ensure the system continues to operate.
working medium:water,liquid,air,light oil(viscosity≤20cst)
medium temperature:-5 ~ 80oC
working pressure:0 ~ 10bar (details see specification table)
working type:semi direct acting(NC)
Valvebody material:brass SS304
sealing material:NBR
interface:G thread NPT thread
voltage:AC220~240V AC 110V AC24V 50/60Hz DC24V DC12V IP65 H degree(iron seal coil: IP54 B degree)
DN10~25 AC 20VA DC 30W DN35~50 AC 45VA DC 31W
Options:
Rc thread sealing material: EPDM VITON VMQ(-10~130oC)
Digital timer LED light connector
Es low power energy saving coil( DN10~25 AC220 V4VA DC24V 4W DN35~50 AC220V 8VA DC24V 7W )
Lead wire iron seal coil
Introduction of Solenoid Valve There are closed chambers in the solenoid valve. There are through holes in different positions. Each hole leads to the oil pipe of different solenoid valves. The middle of the cavity is the valve. The two sides are two electromagnets. Which side of the magnet The coil is energized to the valve body to which side, by controlling the movement of the valve body to block or leak different oil drain holes, and the oil inlet hole is normally open, the hydraulic oil will enter different oil drain pipes, and then pass The pressure of the oil pushes the piston of the cylinder, which in turn drives the piston rod, and the piston rod drives the mechanical device to move. This controls the mechanical motion by controlling the current through and off of the electromagnet.
Different fluid solenoid valves
Our service
We have more than more than 10 years experience in solenoid valves.
Excellent quality control is one of our main principles.
Our design, producing and testing are strictly complied with ISO9001 standard.
Now our products are being exported all over the world.
We provide OEM service, accept customer label, develop the product with your drawings or samples.
Any question, will be replyed within 24 hours.