Kso-g02-91b-7h Double Control Water Solenoid Valves Explosion Proofed
Negotiable
Min.Order:0
working medium:water,liquid,air,light oil(viscosity≤20cst)
medium temperature:-5 ~ 80oC
working pressure:0 ~ 10bar (details see specification table)
working type:semi direct acting(NC)
Valvebody material:brass SS304
sealing material:NBR
interface:G thread NPT thread
voltage:AC220~240V AC 110V AC24V 50/60Hz DC24V DC12V IP65 H degree(iron seal coil: IP54 B degree)
DN10~25 AC 20VA DC 30W DN35~50 AC 45VA DC 31W
Options:
Rc thread sealing material: EPDM VITON VMQ(-10~130oC)
Digital timer LED light connector
Es low power energy saving coil( DN10~25 AC220 V4VA DC24V 4W DN35~50 AC220V 8VA DC24V 7W )
Lead wire iron seal coil
Our service
We have more than more than 10 years experience in solenoid valves.
Excellent quality control is one of our main principles.
Our design, producing and testing are strictly complied with ISO9001 standard.
Now our products are being exported all over the world.
We provide OEM service, accept customer label, develop the product with your drawings or samples.
Any question, will be replyed within 24 hours.
The working pressure can reach 1.3MPa.Normal close and normal open is optional. The port size ranges from 1/8"to2". It can be used in many different medium like air, gas, oil etc. Excellent performance and widely application settle the position in solenoid valves. The annual output is around 720,000pcs.
Characteristic:
1. Pilot operated diaphragm construction with lower power
Consumption for longtime working
2. Applied to pressure system opened from 0.3 bars;
3. Lifespan can be at 1 million cycles.
Medium: Water, Air, Oil, Natural gas, Hot water.
Temperature: NBR: -10 ~ 80
VITON: -10 ~ 120
Pressure: 0.05 ~ 1.60MPa
Body: Brass Or Stainless Steel SUS304
Port Size: 3/8\1/2\3/4\1\11/4\11/2\2
Orifice (mm): DN 15\20\25\32\40\50f
Voltage: DC: 12V, 24V\36V
AC: 220/230V, 110/120V, 24V (50/60Hz)
installation precautions
(1) When installing, please pay attention to the arrow on the valve body should be consistent with the flow direction of the medium;
(2) Do not install in places where there is direct dripping or splashing water and the solenoid valve should be installed vertically.
(3) The solenoid valve should ensure normal operation within the fluctuation range of 15%-10% of the rated voltage of the power supply voltage.
(4) After the solenoid valve is installed, there must be no reverse pressure difference in the pipeline. It needs to be powered on several times to make it suitable for use.
(5) Thoroughly clean the pipe before installing the solenoid valve. The medium to be passed should be free of impurities. Install the filter in front of the valve.
(6) When the solenoid valve fails or is cleaned, a bypass device should be installed to ensure the system continues to operate.