VUVS-L30-M32C-AZD-G38-1C1 Sla Piston 1.2MPa Type Solenoid Valves VUVS-L25-P53C-MD-G14-F8-1C1+G
Negotiable
Min.Order:0
VUVS-LK20-M52-AD-G18-1C1-B Sla Piston 3/8" Type Solenoid Valves 1 Inch
Medium Pressure Sla Explosion Proofed Piston Type Solenoid Valves VUVS-L30-B52-D-G38-F8-1C1+G
6 Inch Sla Medium Pressure Piston Type Solenoid Valves VUVS-LK25-B52-D-G14-1B2-S
AC220V Sla Piston Type VUVS-LK25-M52-AD-G14-1B2-S Solenoid Valves Low Power
The working pressure can reach 1.3MPa.Normal close and normal open is optional. The port size ranges from 1/8"to2". It can be used in many different medium like air, gas, oil etc. Excellent performance and widely application settle the position in solenoid valves. The annual output is around 720,000pcs.
Characteristic:
1. Pilot operated diaphragm construction with lower power
Consumption for longtime working
2. Applied to pressure system opened from 0.3 bars;
3. Lifespan can be at 1 million cycles.
Medium: Water, Air, Oil, Natural gas, Hot water.
Temperature: NBR: -10 ~ 80
VITON: -10 ~ 120
Pressure: 0.05 ~ 1.60MPa
Body: Brass Or Stainless Steel SUS304
Port Size: 3/8\1/2\3/4\1\11/4\11/2\2
Orifice (mm): DN 15\20\25\32\40\50f
Voltage: DC: 12V, 24V\36V
AC: 220/230V, 110/120V, 24V (50/60Hz)
Our service
We have more than more than 10 years experience in solenoid valves.
Excellent quality control is one of our main principles.
Our design, producing and testing are strictly complied with ISO9001 standard.
Now our products are being exported all over the world.
We provide OEM service, accept customer label, develop the product with your drawings or samples.
Any question, will be replyed within 24 hours.
installation precautions
(1) When installing, please pay attention to the arrow on the valve body should be consistent with the flow direction of the medium;
(2) Do not install in places where there is direct dripping or splashing water and the solenoid valve should be installed vertically.
(3) The solenoid valve should ensure normal operation within the fluctuation range of 15%-10% of the rated voltage of the power supply voltage.
(4) After the solenoid valve is installed, there must be no reverse pressure difference in the pipeline. It needs to be powered on several times to make it suitable for use.
(5) Thoroughly clean the pipe before installing the solenoid valve. The medium to be passed should be free of impurities. Install the filter in front of the valve.
(6) When the solenoid valve fails or is cleaned, a bypass device should be installed to ensure the system continues to operate.