Medium Temperature Sla Piston VUVS-L30-P53C-MZD-G38-1C1 Type Solenoid Valves Elektrogas
Negotiable
Min.Order:0
VUVS-L25-M52-MD-G14-F8-1C1+G Sla Piston Type VUVS-LK25-M52-AD-G14-1B2-S Solenoid Valves Festo
Medium Pressure Sla Piston AC110V Type Solenoid Valves Little Friction
YUKEN Sla Piston VUVS-L30-B52-ZD-G38-1C1 Type Solenoid Valves VUVS-LK20-M52-AD-G18-1C1-B
AC110V Sla Piston CKD Type Solenoid Valves VUVS-L20-P53C-MD-G18-F7-1C1+G
working medium:water,liquid,air,light oil(viscosity≤20cst)
medium temperature:-5 ~ 80oC
working pressure:0 ~ 10bar (details see specification table)
working type:semi direct acting(NC)
Valvebody material:brass SS304
sealing material:NBR
interface:G thread NPT thread
voltage:AC220~240V AC 110V AC24V 50/60Hz DC24V DC12V IP65 H degree(iron seal coil: IP54 B degree)
DN10~25 AC 20VA DC 30W DN35~50 AC 45VA DC 31W
Options:
Rc thread sealing material: EPDM VITON VMQ(-10~130oC)
Digital timer LED light connector
Es low power energy saving coil( DN10~25 AC220 V4VA DC24V 4W DN35~50 AC220V 8VA DC24V 7W )
Lead wire iron seal coil
FAQ
Q:What Is Our Main Application?
A:1.Hydraulic system
2.Agriculture machine
3.Construction machina
4.Automobile
5.Local distributors
Q:What Is The Payment Terms?
A:Full order:30% as desposit, the balance before shipment:
Small order /sample ordre: full payment in advance:
Q:Can I Mark My Own Brand On The Pump?
A:Yes. Full order can mark your brand and code.
Q:What Is Our Main Export Market?
A:Europe (41.7%):Italy,Germany,England,France,Holland,Greece,Spain,Portugal,Swissland,Finland,Czekh,Russia,Poland
Asia(40.5%):China,Korea,Singapore,India,Turkey,Iran,Vietnam,Saudi Arabia,Syria,Isreal,Lebanon
Q:How Long Is Guarantee?
A:We give 1 year guarantee.
Our Services
installation precautions
(1) When installing, please pay attention to the arrow on the valve body should be consistent with the flow direction of the medium;
(2) Do not install in places where there is direct dripping or splashing water and the solenoid valve should be installed vertically.
(3) The solenoid valve should ensure normal operation within the fluctuation range of 15%-10% of the rated voltage of the power supply voltage.
(4) After the solenoid valve is installed, there must be no reverse pressure difference in the pipeline. It needs to be powered on several times to make it suitable for use.
(5) Thoroughly clean the pipe before installing the solenoid valve. The medium to be passed should be free of impurities. Install the filter in front of the valve.
(6) When the solenoid valve fails or is cleaned, a bypass device should be installed to ensure the system continues to operate.
Our advantage:
(1)We can do the designs according to customers' requirements.
(2)We can open customers' own mold as per their requirements.
(3)We can offer you a good after-sell service.
(4)Prompt delivery.
(5)Small order is welcome, the MOQ is 1 pc.